G2424-S200
Installation
Installation requirements
Air quality
For optimum performance and maximum product life we recommend the use of compressed air with
a maximum dew point of +10°C (50°F). We also recommend to install an Atlas Copco refrigeration
type air dryer.
Use a separate air filter which removes solid particles larger than 30 microns and more than 90% of
liquid water. Install the filter as close as possible to the product and prior to any other air preparation
units to avoid pressure drop.
Make sure that the hose and couplings are clean and free from dust before connecting to the tool.
Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a lu-
bricator.
Air lubrication guide
Brand
Atlas Copco
Q8
Shell
Compressed air connection
WARNING Air under pressure can cause serious injury
Always shut off the air supply, drain hose of air pressure and disconnect the tool from air supply;
when not in use, before making any adjustments to the product - for example changing acces-
sories, or when making repairs.
WARNING Whipping hoses can cause serious injury
Always make sure that there are no damaged or loose hoses or fittings.
WARNING Working pressure
Do not exceed the maximum working pressure.
For correct air pressure and hose size, see section Technical data.
Make sure that the hose and couplings are clean and free from dust before connecting to the tool.
Installation instructions
Installation of vibrating tools
It is recommended that a minimum length of 300 mm (12") of flexible hose for compressed air is inserted
between a vibrating tool and the quick-action coupling.
EN
© Atlas Copco Industrial Technique AB - 9839 0487 00
Air lubrication
Optimizer (1 liter) 9090 0000 04
Chopin 46
Shell Air Tool Oil S2 A 320