Télécharger Imprimer la page

Dell Networking C1048P Guide De Mise En Route page 29

Publicité

Les langues disponibles

Les langues disponibles

Dell# show interface port-channel br
Example of Provisioning a Port Extender
Dell(conf)# feature extended-bridge
Dell(conf)# pe provision 2
Dell(conf-pe-2)# stack-unit 0 type c1048p
Dell(conf-pe-2)# cascade interface tengigabitethernet 0/1–2
Dell(conf-pe-2)# exit
Dell(conf)# interface range tengigabitethernet 0/1-2
Dell(conf-if-te-0/1–2)# no shutdown
Dell(conf-if)# end
Dell# show pe brief
--
Port Extenders Information
----------------------------------------------------------
PE-id
Status
Stack-size
----------------------------------------------------------
2
online
11
NOTE: If the status of a port extender is error, communication with an
attached C9010 was unsuccessful, possibly due to a mismatch in
software version (SVM) or another communication error. Wait five
minutes for an auto-upgrade of the port extender to be performed. If
the status does not change to online, contact Dell Networking Support
for assistance.
Dell# show pe 2
Codes:
A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown
Error
PE-ID assigned: 2
Status: online
System Mac: 34:17:eb:00:bb:11
Type
1
C1048P
--
System-MAC
34:17:eb:00:bb:
27