Télécharger Imprimer la page

Using The Device - Dometic BUTTNER MT PL 300 SI Instructions De Montage Et De Service

Onduleur sinusoïdal pur

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
fig. 1,
Description
page 3
6
Plug-in socket
7
Grounding terminal
8
Output socket
9
Front panel
10
Plug-in socket
11
Plug-in socket
5. Make sure that all fasteners are properly tight-
ened and connections are secure, including
the connections at the fuse.
Connecting neutral line to ground
!
WARNING! Electrocution hazard
The installation may only be carried out
by a qualified electrician.
In applications where the inverter supplies multiple
sockets, a protective device must be used. In this
case the connection of the neutral (N) line to the
protective ground (PE) is required.
MT PL300-1500 SI
➤Connect the chassis ground terminal and the
neutral terminal of the protective device using a
2
cross-section (fig. a, page 8).
wire with 4 mm
MT PL 2000 SI
➤Strip both ends of a wire with 4 mm
tion (fig. b, page 8, 3).
➤Using a screwdriver release the locking tab
(fig. b, page 8, 1).
➤Insert the wire into the terminal (fig. b, page 8,
2).
230 V AC
Remote control
Optional 12 V
remote signal
input
2
cross-sec-
4445103623

Using the device

Front panel
fig. 4,
Description
page 4
1
Check LED
2
Power LED
3
Main switch
Remote control
l
fig. 3,
Description
page 4
1
Check LED
2
Extern
3
Inverter
4
On/Off button
Indicates restricted
operation.
Indicates the inverter is
switched on and 230 V
AC voltage is present at
the output.
• Inverter on, indepen-
dent of a remote sig-
nal input or remote-
control status.
• Inverter off.
• Remote mode allows
the operation of the
inverter from the
remote control or the
remote signal control
input.
Indicates restricted
operation.
Indicates that the
inverter is activated from
the additional remote
signal input with 12V DC
control signal supplied.
Indicates that the
inverter is in operation
and 230 V AC is present
at the output.
Used for turning the
inverter on or off manu-
ally, when the device
main switch is in Remote
position.
13

Publicité

loading