3.3.5 Transformer connections
"
!
CAUTION:
"
!
CAUTION:
lead, and protect these against mechanical loads.
1. A 220 V / 230 V, 50 Hz power socket conforming to the VDE specifications is required
2. The diagram for the transformer connections is given in the figure below:
Take hold of the plug only to remove it from the power socket.
The power lead must be laid without any loops or kinks and should not pass around sharp
edges.
The power cable leading to the control pendant must be protected against squeezing.
4

Maintenance

The lifetime of the bed is influenced by its use, storage, regular maintenance, servicing and
cleaning.
4.1

Regular Maintenance

The maintenance activities to ensure a good condition for your Vermeiren bed are described
below:
Before every use
Every 8 weeks: inspection or adjusting of
Every 6 months or for every new user
Risk of injury - Do not touch the plug with wet hands.
Risk of injury - Do not place any objects on the connection and the
#
Check the tyres and make them clean. If necessary change the tire.
#
Check the brakes and adjusted if necessary.
#
Check the bed (cleanliness, cracks, damage on structural parts ... .) and make
it clean. If necessary change the coating.
#
Check the cables for visible signs of damage and whether all plugs are
properly inserted as indicated in the instruction manual. In the case of
damage immediately unplug the power lead.
#
Check the functioning of the mechanically adjustable elements (side railings,
lifting pole, foot-end).
#
Check that the manual controls function properly. If a function is faulty, kindly
disconnect the power plug.
#
Operation of the sliding rail of the side railings (headrest and foot-end)
#
Placement of the slats in the slatted frame
#
The condition of the wooden parts
#
Lifting pole (fit / deformation)
#
General review
#
Disinfection
#
Cleanness
#
Lubricating from moving parts (do not lubricate the motors)
#
Airing of the use mattress
Interval, Interval 120cm, Interval 140cm
To be connected in the sequence indicated.
1 = Undercarriage motor
2 = Headrest motor
3 = Knee-bending motor (if necessary)
A = Manual control
B = Power distribution
Power socket 220V/230V, 50 Hz
!"#$%&+%