In functioning mode, after carrying out filter
maintenance, press the key until hearing the
sound signal. The flashing LED 1 (grease filter)
or 2 (carbon filter) stops flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood
command electronics will be excluded.
This function can be useful during the product
cleaning operations.
Just repeat the operation to reinsert the
electronics.
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid
detergent.
DO
NOT
INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Steam screen
The steam screen must always be left closed and
opened only for maintenance (e.g. cleaning or changing
filters).
Grease filter
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor
slightly, but this does not affect its filtering capacity.
Open the steam screen.
Pull the handle downwards and extract the filter. Fig. 2
Charcoal filter (filter version only)
Fig. 3
It absorbs unpleasant odors caused by cooking.
The charcoal filter can be washed once every two months (or
when the filter saturation indication system – if envisaged on
the model in possession – indicates this necessity) using hot
water and a suitable detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle function and leave
dishes out).
Eliminate excess water without damaging the filter, then put it
in the oven for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and when the cloth is
damaged.
Fig. 3
Montage
Open the steam screen and remove the grease filter.
CLEAN
WITH
TOOLS
Install the carbon filter on the back of the grease filter and
fix with two rods.
Attention! The rods are included in the carbon filter
packing and not on the hood.
To dismantle the filter act in the reverse manner.
Replacing lamps
Fig. 4
Disconnect the appliance from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Use a small screwdriver as a lever on the borders of the
lamp in order to remove the lightbulb.
Replace the damaged lamp.
Use 2,6W-GU4 max LED lamps only. For more details,
check enclosed leaflet "ILCOS D" (alfanumeric position
"3c).
Carry out the replacement and mount the new lightbulb
by following instructions in the reverse.
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.