Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Avoid overexposure to fumes and gases. Always keep your head out of the fumes.
Do not breathe the fumes. Use enough ventilation or exhaust, or both, to keep
fumes and gases from your breathing zone and general area.
Where ventilation is questionable, have a qualified technician take an air
sampling to determine the need for corrective measures. Use mechanical
ventilation to improve air quality. If engineering controls are not feasible, use
an approved respirator.
Work in a confined area only if it is well ventilated, or while wearing an
air-supplied respirator.
Follow OSHA guidelines for Permissible Exposure Limits (PEL's) for various
fumes and gases.
Follow the American Conference of Governmental Industrial Hygienists
recommendations for Threshold Limit Values (TLV's) for fumes and gases.
Have a recognized specialist in Industrial Hygiene or Environmental Services
check the operation and air quality and make recommendations for the specific
welding or cutting situation.
10. Always keep hoses away from welding/cutting spot. Examine all ho-
ses and cables for cuts, burns, or worn areas before each use. If any damaged areas
are found, replace the hoses or cables immediately.
11. Read and understand all instructions and safety precautions as
outlined in the manufacturer's Manual for the material you will weld
or cut.
12. Proper cylinder care. Secure cylinders to a cart, wall, or post, to prevent
them from falling. All cylinders should be used and stored in an upright position. Ne-
ver drop or strike a cylinder. Do not use cylinders that have been dented. Cylinder
caps should be used when moving or storing cylinders. Empty cylinders should be
kept in specified areas and clearly marked "empty."
13. Never use oil or grease on any inlet connector, outlet connector,
or cylinder valves.
14. Use only supplied Torch on this Welder. Using components from other
systems may cause personal injury and damage components within.
15. People with pacemakers should consult their physician(s) before using this
product. Electromagnetic fields in close proximity to a heart pacemaker could
cause interference to, or failure of the pacemaker.
EN
Rev. 02.03.2017
44
44
16. USE PROPER EXTENSION CORD.
Make sure your extension cord is in good condition. When using an extension
cord, be sure to sue one heavy enough to carry the current your product will
draw. An undersized cord will cause a drop in line voltage resulting in loss of
power and overheating. A 50 foot extension cord must be at least 12 gauges in
diameter, and a 100 foot extension cord must be at least 10 gauges in diameter. If
in doubt, use the next heavier gauge. The smaller the gauge number, the heavier
the cord.

1. DEVICE PARTS

Apparatuses necessary for welding construction
N O. Standard products
RMKS
needed
1
TIG welding gun
WP-18
2
Workpiece
-
3
Earth clamp
300A
The connection diagram of the welder is shown below.
Be sure to use this welding machine with the specified
NOTICE
!
welding gun, earth clamp together; it will affect the welding
performance and may damage the machine.
Rev. 02.03.2017
EN
N O. Standard products
RMKS
needed
4
Distribution box
Three-phase
400V
5
Pedal switch
-
6
Flow adjuster
-
45

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Stamos s-digitron 250pStamos s-digitron 315p

Table des Matières