Exhaust air flow control at the feed cylinder can
be adjusted through the opening.
It must be assured that the bottom of the box is
completely opened up and that the box is
squarely seated in the guide provided for this
purpose in a positive locking manner. It must also
be determined whether or not there's any height
offset between the bottom of the box and and the
module's support surface. If this is the case, the
height of the magazine must be adjusted.
If the box is not correctly opened up or if it's
excessively squeezed, this can be adjusted by
loosening the feed cylinder's 4 mounting screws
(see photo).
After the box has been opened up, adjustment of
the setup cylinder can be started. The retainer
screws are loosened first of all. The setup cylinder
is then advanced manually in order to determine
whether or not the box top is pressed against the
folding mechanism's closing flap.
If the height of the setup cylinder also needs to
be adjusted, corresponding screws are located on
the back of the mounting bracket.