5. Press the
button on the rotating laser.
▶ The inclined plane mode LED on the rotating laser then blinks.
▶ The inclined plane mode symbol is shown on the PRA 30 laser receiver.
6. Begin automatic alignment by double-clicking the
▶ The rotating laser inclines the laser plane automatically until the mark at the PRA 30 laser receiver is
reached. An signal tone is emitted repeatedly during this procedure.
▶ The rotating laser levels itself once the position has been reached. Successful completion is indicated
by a continuous signal tone with a duration of 5 seconds. The
▶ If automatic alignment cannot be completed successfully, short signal tones are emitted and the
indication in the display disappears.
7. Read the inclination from the PRA 30 laser receiver within 5 seconds.
8. Stop automatic inclination before completion by double-clicking the
receiver.
If the rotating laser begins the automatic search in the wrong direction, press the
change the search direction.
5.12
Alignment using electronic inclination alignment (e-targeting)
Electronic inclination alignment optimizes manual alignment of the rotating laser. The electronic
method is more accurate.
The rotating laser, depending on the application, is mounted or positioned securely.
The PRA 30 laser receiver and the rotating laser are paired.
The PRA 30 laser receiver and the receiving side of the rotating laser are facing each other and in direct
line of sight. The best receiving side of the rotating laser is the side at which the battery is inserted.
1. Set the inclination of the laser plane automatically. → page 12
2. Press the
button on the rotating laser.
▶ If both arrows blink, the PRA 30 laser receiver is receiving no signal from the rotating laser.
▶ Use the marking notch on the PRA 30 laser receiver to bring the rotating laser into alignment.
▶ If the left arrow lights
▶ If the left right arrow lights
▶ If both arrows light constantly for 10 seconds, alignment of the PRA 30 laser receiver is correct and
the procedure ends.
3. Secure the rotating laser on the tripod in this position.
4. Stop electronic inclination alignment before completion by double-clicking the
laser.
5.13
Deactivating the shock warning function
1. Switch the laser on. → page 10
2. Press the
button.
▶ The shock warning deactivation LED lights constantly, indicating that the function has been
deactivated.
To return to standard operating mode, switch the laser tool off and then switch it back on again.
5.14
Activating / deactivating sleep mode
Sleep mode may be activated on the rotating laser during breaks between work or during other
activities. All settings concerning the laser plane or inclination are retained while in this status. Sleep
mode saves power and extends battery life.
Please also refer to "PRA 30 laser receiver menu options" for information about settings.
1. Switch the laser receiver off.
*2134493*
button on the PRA 30 laser receiver.
, turn the rotating laser clockwise.
, turn the rotating laser counterclockwise.
2134493
symbol disappears.
button on the PRA 30 laser
button on the rotating
English
button to
13