Parameter programming for atmospheric pressure boiler version - pushbutton panel code 50592
Number Parameter
0
Wash time cycle 1
1
Wash time cycle 2
2
Wash time cycle 3
3
Wash time cycle 4
4
Boiler temperature setting
5
Tank temperature setting
6
Energy-saving threshold cycle 1
7
Energy-saving threshold cycle 2
8
Energy-saving threshold cycle 3
9
Energy-saving threshold cycle 4
A
Tank draining time
B
Water fi lling time-out
C
Supply water hardness
D
Hot rinse time
E
Drain pump enabling
Atmospheric pressure boiler
F
fi lling time out
G
Flowswitch enabling
H
Start enabling with door
I
Optionale parameter
J
Regeneration cycle enabling
Tabella 3
INSTALLER SECTION
Min.
Max.
Measure
25
300
25
300
25
300
25
300
149 (65)
210 (90)
121 (50)
180 (65)
19 (10)
73 (40)
19 (10)
73 (40)
19 (10)
73 (40)
19 (10)
73 (40)
10
99
60
600
0
40
10
30
0
1
60
600
0
1
0
1
0
1
0
1
Unit of
Cycle
standard
s
120s
s
180s
s
240s
s
300s
°F (°C)
185°F (85°C)
°F (°C)
160°F (71°C)
°F (°C)
19°F (10°C)
°F (°C)
27°F (15°C)
°F (°C)
30°F (18°C)
°F (°C)
36°F (20°C)
s
30s
s
240s
°f
0
s
15s
0
s
240s
0
0
0
0
USA
Notes
step 5s
step 5s
step 5s
step 5s
step 1-3°F (1/2°C)
step 1-3°F (1/2°C)
step 5s
step 5°f
0=cut out
5=760 lt
10=380 lt
15=300 lt
20= 240 lt
25=200 lt
30=160 lt
35=120 lt
40=100 lt
step 1m
1=enabled
step 5s
1=enabled
1=enabled
1=enabled
1=enabled