*ATTENTION! FURTHER SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
COMPLY WITH LEGISLATION IN FORCE!
Having manually changed the parameters FSto, FStc, SLdo, SLdc, tSMo, tSMc, the display will show the writing "PRG" since a complete manoeuvre
must be controlled to allow the control unit to learn the new operating parameters.
Having executed this manoeuvre, the writing disappears.
MENU
It enables and disables automatic closure.
TCA
On: automatic closure enabled.
Off = automatic closure disabled
Enabling and disabling sharing function.
On: condominium function enabled. The S.S. or transmitter impulse has no effect during the
IbL
opening phase.
Off: condominium function disabled.
Enables or disables the condominium function during TCA counting.
ibca
On: condominium function enabled. The PP or transmitter pulse has no effect during TCA counting.
Off: apartment complex function disabled.
Select the operating mode of the "P.P. button" and the transmitter.
PP
On: "Operation"; OPEN> CLOSE > OPEN>
Off: "Operation"; OPEN>STOP>CLOSE>STOP>
Enables or disables pre-flashing.
PRE
On: Pre-flashing enabled. The flashing light activates 3s before the motor starts.
Off: Pre-flashing disabled.
It enables and disables rapid closure.
On: rapid closure enabled. With the door open or in the opening phase, intervention of the pho-
SCL
tocell causes automatic closure 3 s after complete opening.
Active only with TCA:ON
Off = rapid closure disabled
Person present function enabled or disabled.
On: Person Present Operation
htr
The OPEN/CLOSE keys must remain pressed during the movement. Opening the STOP input
stops the motor. All the safety inputs are disabled.
Off: Automatic operation.
It enables or disables the Person present function in closure.
On: Person Present Operation
chtr
Operation of OPEN button is impulsive, while the closure manoeuvre only takes place maintaining
the CLOSE (Person present) button pressed.
Off: Automatic operation.
Selection of the flashing indicator light operating mode during the TCA time
ltca
On: Flashing indicator light on during TCA
Off: Flashing indicator light off during TCA
It enables or disables reception of the transmitters duplicated by the "AK" series.
cvar
On: AK transmitters reception enabled
Off: AK transmitters reception disabled.
Selection of the PHOT input operating mode.
On: Active PHOT input both in closure and opening.
In opening: opening of the contact caused by stoppage of the motor, when the photocell is
free, the motor restarts in opening.
phcl
In closure: opening of the contact causes stoppage of the motor, when the photocell is
free, the motor inverts the running direction (opens).
Off: PHOT input enabled only in closure.
In closure: opening of the contact causes stoppage of the motor and instantaneous inversion
of the running direction (opens).
It enables or disables remote learning of the radio transmitters, as indicated in the "Transmitters
remote learning" paragraph.
rem
On: Remote learning enabled.
Off: Remote learning disabled.
It enables or disables the "ESA" energy saving functionality.
On: The control unit, once the manoeuvre has terminated and enabling time is up of the service
light, removes the power supply to the accessories output, setting in stand-by status.
esa
Off: Energy saving disabled. To use if you want to have the accessories power supply always
enabled, for example if using 24 Vdc, or other devices that need to be always powered.
Note: If the ESA logic is set to ON, prior to performing each manoeuvre, the unit checks the
switching of the photocell contact. If the check fails, the operation does not start.
(
)
9.2) LOGIC
LOG
FUNCTION
ON-OFF-(DEFAULT)
MEMO
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
OFF
(OFF)
(ON)
(OFF)
(ON)
(ON)
EN
21