AC401 international.qxd
STEP 9
ALARMS AND VIBRATION (VIBRATION NOT AVAILABLE IN SOME COUNTRIES)
STEP 10
ROOM TEMPERATURE CONTROL
STEP 11
BATTERY MODE AND WARNINGS
Low battery indicator
Low battery
indicator
Red light
STEP 12
ADDITIONAL FUNCTIONS
6/10/08
11:44 AM
Page 5
This menu will appear ONLY if the vibration option is available on your unit. It allows you to
choose between the following notification options :
- Alarm only
- Vibration only
- Alarm and vibration
NOTE : The vibration mode will not work when the batteries are low or if the parents unit
is on the charger.
• Press MENU and choose the desired option. The wave icon is for the vibrationmode and
the bell icon is for the alarm mode.
• Select the desired option, using the arrows. Press SELECT.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
Your Angelcare© monitor can also monitor your baby's room temperature and let you know
when the temperature is to high or too low. A tripple BEEP will be heard if the temperature
reaches levels out of the chosen range.
• Press MENU, the snow flake and sun icons and the word OFF will appear on the screen.
• Turn it ON or OFF using the arrows.
• Press SELECT.
• If you select to have the room temperature control ON, Press MENU.
The SNOW FLAKE icon will appear, with the temperature. Select the desired lowest
temperature with the arrows and press SELECT.
• Press MENU. The SUN icon will appear, with the temperature. Select the desired highest
temperature with the arrows and press SELECT.
• Press EXIT as this was the last available programmable function.
• The monitor will revert to battery mode during a power failure only if batteries are inserted
in both units.
• It is also possible to use the Angelcare© monitor in places where electricity is not available.
• When the nursery unit's low battery RED light is flashing, its batteries need to be replaced.
On the screen of the parents unit, the battery icon flashes and the nursery unit icon appears.
A short BEEP will also be heard every 15 seconds for about 30 minutes, until the unit shuts
itself off.
• Parents unit should be recharged when icon is clear (will not flash) and a beep sound is
heard. A short BEEP sound will be heard every 15 seconds until the unit shuts itself down.
Note: Do not use Alkaline batteries in the parents unit.
IMPORTANT : If the "Out of range" function is ON, when the nursery unit shuts itself off, the
"Out of range" signal will be heard and displayed on the parents unit.
• CHANNEL SELECTION :
• TEMPORARY MUTE :
•CONNECTING THE PARENTS UNIT TO THE NURSERY UNIT:
• PAGING:
If the transmission is not clear, or if you hear parasite sounds,
you should change the channel. Press and hold the SELECT
button to change the channel (with the arrows). Then press the
SELECT button again to confirm.
If you want to mute the sound for 2 minutes, press the center
EXIT button. To reactivate the sound before the 2 minutes have
elapsed, press EXIT again. You can also turn the alarm off by
pressing the same button (this does not apply to the low
battery alarm).
If you lose the connection between the 2 units, press and hold
the MENU button on the parents unit, the "out of range"
indicator will flash. Press and hold the top button of the nursery
unit to re-connect to the nursery unit. The Tic light flashes.
If you want to locate the parents unit, press the top button of
the nursery unit.
5
E
N