Alarms Table - Extraflame LP30 Manuel Utilisateur

Masquer les pouces Voir aussi pour LP30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
Display
FAN FAILURE
FLUE PROBE
HOT FUMES
NO FLOW ALARM
NO IGNITION
BLACK-OUT NO IGN.
NO PELLETS
DEPR ALARM
DEPR SENSOR DAMAGE
H2O OVERTEMP ALARM
MINIMUM PRESSURE
ALARM
TRAPDOOR BLOCK
WATER PROBE

ALARMS TABLE

ALARMS TABLE
ALARMS
Reason
Indicates the presence of an alarm.
Flue gas motor fault
Flue gas probe fault.
High flue gas temperature
The door is not closed correctly.
The ash drawer is not closed
correctly.
The combustion chamber is dirty.
The flue exhaust or air supply pipe
is blocked.
The pellet feed-box is empty.
Pellet feed calibration inadequate.
No current during the ignition
phase.
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed
pellets.
The door is not closed correctly.
The ash drawer is not closed
correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked
flow sensor faulty
sensor disconnected
the water in the boiler has
exceeded 95°C.
Possible air in the system.
Insufficient circulation.
No or inadequate safety zone.
Possible pump anomaly.
the system pressure read by the
pressure switch is too low.
Possible presence of air in the
system.
Possible lack of water or leaks
due to anomalies in some system
component.
The automatic cleaning of the burn
pot results blocked.
H2O probe faulty
Solution
To reset the alarm, just hold "ignition/switch-off" for 3 seconds
when the boiler is cold.
contact after-sales centre
contact after-sales centre
check the calibration of pellet regulation. If this cannot be solved,
contact an authorised technician
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check cleanliness if the air supply pipe and the flow sensor
Check for the presence of pellets in the feed-box.
Regulate the pellet flow
Check the procedures described in the "Ignition" chapter.
Take the boiler to OFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
Check for the presence of pellets in the feed-box.
Adjust pellet flow (see "Pellet feed adjustment").
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check the mechanical pressure switch (air side)
contact after-sales centre
contact after-sales centre
contact after-sales centre
Switch off the machine, wait for complete cooling and repeat the
ignition cycle.
If the problem persists, the reset operations must be carried out by
an authorised technician.
contact after-sales centre
47

Publicité

Table des Matières
loading

Table des Matières