4.0 - FIRST START-UP
• Before start-up, make sure that all the instructions on the rating plate, including the direction of flow, are observed;
• After having gradually pressurised the system, check the tightness and operation of the filter.
4.1 - RECOMMENDED PERIODIC CHECKS
• Use a suitable calibration tool to ensure the bolts are tightened as indicated in 3.2;
• Check the tightness of the flanged/threaded connections on the system;
• Check the tightness and operation/efficiency of the filter;
The final user or installer is responsible for defining the frequency of these checks based on the severity of the service conditions.
5.0 - MAINTENANCE
• Before carrying out any dismantling operation on the device, make sure that there is no pressurised gas inside.
REPLACING THE FILTER ELEMENT (2)
• Remove the cover (1) by loosening the fastening screws (5);
• Extract the filter element and check its conditions. Blow it and clean it and, if necessary, replace it.
• Reassemble it in its initial position, checking that it is placed between the special guides (4) (see fig. 1-2-3);
• Check the conditions of the sealing O-ring (6) of the cover (1), and replace it if necessary (recommended);
• Make sure the O-ring (6) of the cover (1) is inside the provided groove;
• Reassemble the cover and secure it in its original position, being very careful not to "pinch" or damage the O-ring during tightening;
• Tighten the screws (5) gradually, following a "cross" pattern, until the torque (tolerance -15%) indicated in the table below
is reached. Use a calibrated torque wrench to do this.
• Check the body/cover seal.
Screw
Max. torque (N.m)
6.0 - TRANSPORT, STORAGE AND DISPOSAL
• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (ex. painting, cataphoresis, etc.) it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product is to be disposed of in compliance with the legislation in force in the country where
this operation is performed.
FM
M5
M6
Stainless
Galvanised
Galvanised
Steel
6
4.5
10
M8
Stainless
Stainless
Galvanised
Steel
Steel
7.5
25
18.5
12
Madas Technical Manual - 6|6.3 - REV. 0 of 10
M10
M12
Stainless
Galvanised
Galvanised
Steel
49.5
37
84.5
Stainless
Steel
63.5
Oct 2018