Setting The Air Temperature; Setting The Humidity Level; Food Holding Guide - Hatco FLAV-R-SAVOR FSHC-12W1 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Setting the Air Temperature

Use the following procedure to set or change the air
temperature.
1. press the
key to enter temperature mode ("tSp" will
appear on the CaBINET TEmpERaTURE display).
2. press the
key again to show the current temperature
setting.
3. press the
key or
temperature. The temperature range is 80°–200°F
(27°–93°C) in single degree increments. See the "Food
Holding Guide" in this section for recommendations.
4. after the desired temperature is set, wait 15 seconds
without pushing any keys for the cabinet temperature
display to return automatically to operational mode.
Setting the air Temperature
NOTE: Temperature and humidity settings may vary depending
upon product make-up and consistency. The CaBINET
TEmpERaTURE display shows the lowest temperature
point inside the cabinet, not the product temperature.

Food Holding Guide

Type of Food
Biscuits
Chicken pieces (Fried)
Croissants
Fruit pies
Onion Rings
pizza — Thick Crust
Thin Crust
pretzels
Wrapped Sandwiches
NOTE: All times and settings are recommendations only and may vary depending on product preparation, cooking time, internal
food temperature, location of unit in operation, geographic region of particular operation, and frequency of door openings.
Form No. FSHC1217Wm-0515
key to reach the desired
Maximum
Holding Time
4 Hours
4 Hours
4 Hours
3-1/2 Hours
1/2 to 2 Hours
1 Hour
1 Hour
3 Hours
2 Hours

Setting the Humidity Level

Use the following procedure to set the humidity level on
humidified units.
1. press the
appear on the CaBINET TEmpERaTURE display).
2. press the
key again to show the current humidity level.
3. press the
key or
level. Humidity range is 0 through 5 (1 is the lowest amount
of humidity and 5 is the highest, 0 is no humidity). See the
"Food Holding Guide" in this section for recommendations.
4. after the desired humidity level is set, wait 15 seconds
without pushing any keys for the cabinet temperature
display to return automatically to operational mode.
The water pan capacity permits uninterrupted operation for
approximately 4-8 hours, depending on the humidity and
temperature settings as well as how frequently the door is
opened. WARNING! Electric Shock Hazard — Do not overfill
water reservoir.
Humidity
Setting
3
1
1
3
1
1
2
3
3
11
OPERATION
key to enter humidity mode ("hSp" will
key to reach the desired humidity
Setting the Humidity Level
Air Temperature Setting
°F
140
170
140
140
180
185
180
140
170
°C
60
77
60
60
82
85
82
60
77

Publicité