At least 25 mm
The refrigerator must be adjusted to a vertical position
in both directions. Use the feet on the refrigerator to
adjust its position.

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must be 37 mbar for Propane and
28 mbar for Butane. Check that this is stated on the data
plate.
The refrigerator is not designed for operation on town
gas or natural gas.
CAUTION! CHECK THAT THE GAS SUPPLIED
TO THE REFRIGERATOR IS AT THE CORRECT
PRESSURE. SEE THE REDUCING VALVE ON
THE LP GAS CONTAINER.
The gas installation and servicing should only be carried
out by an authorized, qualified person and must conform
to all relevant national and local regulations.
The gas supply pipe should be connected to the gas inlet
of the gas control valve by means of a suitable threaded
coupling.
In making the connection to the refrigerator, a union gas
cock of an approved bottled-gas type must be incorpo-
rated in the supply line in a position which is readily
accessible to the user. For eventual servicing purposes,
the union should be on the outlet side of the cock and
the pipework should be positioned so as not to prevent
the refrigerator from being readily withdrawn.
34
From the side
Wall
From
25
above
Wall

ELECTRICAL CONNECTION

The electrical installation must be carried out in a proper
and durable manner, taking into account all relevant
regulations and codes of practice.
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured mark-
ings identifying the terminals in your plug, proceed as
follows:
-
the wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked
with the letter E or by the earth symbol
coloured green or green and yellow,
-
the wire which is coloured blue must be connected to
the terminal which is marked with the letter N or
coloured black,
-
the wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.
WARNING- THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in this mains lead are coloured in accordance
with the following code:
-
green/yellow:
earth
-
blue:
neutral
-
brown:
live
Your appliance is already fitted with a 13 amp.(B.S. 1363)
fuse plug incorporating a 3 A fuse. If it does not fit your
socket the plug should be cut off from the mains lead
and an appropriate plug fitted.
Throw away the cut off plug; do not insert it in a 13 A
socket-outlet elsewhere in the house as this could cause
a shock hazard.
The fuse cover must be re-fitted when changing the fuse.
Never use the plug without the fuse cover.
The appliance must be protected by a 3 amp. fuse, ASTA
approved to B.S. 1362.
240 V Supplies.
Check that the voltage stated on the data plate is the
same as the mains voltage in use (240 V).
Plug the 240 V refrigerator power cord into an easily
accessible earthed wall socket.
Electrical leads must be routed and secured so
that they cannot come into contact with hot or
sharp parts of the refrigerator.
Lighting
The refrigerator is provided with a battery power interior
light.
The battery box is at the rear of the refrigerator.
Four batteries, type LR20 1,5 volts are to be used.