10.5 Outputs
Outputs:
Max. switching voltage:250 V AC / 30 V DC
Max. switching current: 2 A
Max. switching capacity:
Mechanical service life:1x10
Electrical service life: 5x10
Output response time: < 20 ms, max. 4 Hz
Insulation coordination: Basic insulation
UL ratings:
10.6 Fuses / overcurrent limitations
Input signals: In case of a failure, the current
must be limited to a safe value via the inputs.
We recommand a 0.1A/T fuse.
Relay: The maximum switching current of 2A
shall in no case be exceeded.
10.7 Connections
7 plug-in screw terminals, pitch 5.08, cable
cross section max. 2.5 mm.
10.8 Insulation coordination
Connections among each other
x.901.xxx.820: only the counting and reset
inputs have double / reinforced insulation
x.901.xxx.850: generally only basic insulation
10.9 Consumables
Battery: order code: N060045 Tadiran Lithium
SL350/S ½ AA 3.6V 1.2Ah
Page 8 | ENG
bistable relay with poten-
tial-free contact – pro-
grammable as normally
open or normally closed
60 VA / 30 W
7
(1A 30Vdc)
5
2A, 30Vdc, 50°C