CONNECTION OF THE POWER SUPPLY CABLE
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
•
8.1).
Unscrew the screw "D" and open completely the cable clamp "E" (figs. 8.2 - 8.3 - 8.4).
•
Position the U bolts "F" onto terminal board "G" (figs. 8.2 - 8.3 - 8.4) according to the
•
diagrams in fig. 8.5.
•
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagrams in fig. 8.5.
•
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D").
•
Close the terminal block cover (check the two hooks "A" are correctly hooked).
NOTE: The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
Fig. 8.1
A
FEEDER CABLE SECTION
"TYPE H05RR-F or H05VV-F"
230 V ac
3 x 6 mm
400 V 3N ac
5 x 2,5 mm
400 V 2N ac
4 x 6 mm
(**) Connection with wall box connection.
–
Diversity factor applied.
–
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.