Annexe
7
Annexe
7.1
Exemple de rapport de test de bon fonctionnement
Customer Data
Levelflex M
Instrument Type
Order Code
Probe Length
Serial Number
Tag
Initial Calibration
Reference
No.
1
2
Recurrent Test
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Uncertainty of measurement: ±6 mm
14
FMP43
ATSTDJB21A4A
950mm
7806420104E
LI200A
Date
Time
Cable
Nr. 1
07.03.2007
11:43
07.03.2007
11:50
Date
Time
Reference- No. 1
09.08.2007
9:37
06.12.2007
14:54
03.03.2008
8:32
Calibration Kit FMP43
Order Code
Serial Number
Cable
Cable
Cable
Nr. 2
Nr. 3
Nr. 4
x
x
x
Recurrent Test Values
Reference- No. 2
151 mm
784 mm
152 mm
785 mm
150 mm
780 mm
Ambient conditions:
• Rel. humidity max. 80%; condensation not permissible
• Temperature range: 10...40°C
• Temperature variation to preceding calibration: ±5K
Levelflex M FMP43
Logo
5200-9785
5804032014A
Reference Value
Person in
(measured distance)
Charge
152 mm
783 mm
Person in
Test result
Charge
o.k.
o.k.
o.k.
Endress+Hauser