Floor Standing Cabinet Type
[In Cooling operation]
In cooling operation, set the air outlet flap with a horizontal
set point so that the cold air diffuses the whole room.
[In Heating operation (For Heat-pump model only)]
In heating operation, set the air outlet flap with a downwards
set point so that the hot air blows towards the floor.
How to change the air outlet port
Change the air outlet port using the following procedure.
1
Remove the two fixing screws on the air outlet
port. (The fixing screws are reused.)
2
Remove the discharge port, by pushing up on
the rear side, to a point where you can remove it
from the rear clip.
3
Lift the air outlet port upwards and remove it.
4
Reverse the air outlet port and attach it to the
main unit.
Pay attention so that four claw hooks (two at rear and two
at the lower sides) are hooked on the mounting position.
5
Be sure to tighten the air outlet port with the
removed fixing screws so that the air outlet port
does not come off.