Right/Left air direction adjustment
To change the air outlet direction to the right or left side, set the vertical flap located behind the horizontal flap
to the desired direction.
High Wall Type
Adjustment of air flow direction upwards/downwards
[In Cooling operation]
In cooling operation, use the horizontal flap with a horizontal set point
so that the cold air diffuses the whole room.
[In Heating operation (For Heat-pump model only)]
In heating operation, use the horizontal flap with a downwards set
point so that the hot air blows towards the floor.
• If cooling operation is performed with the louver set at a down-
wards position, dew may form on the surface of the cabinet or
the horizontal flap resulting in possible dripping.
• If heating operation is performed with the louver set in a hori-
zontal position, the room temperature may not be equal i.e.
there may be a large variance between one side of the room
with the other.
• Do not move the horizontal flap directly with your hands; other-
wise a fault/error may be caused. Select the direction of the
horizontal flap using the
The horizontal flap will not stop immediately even if the switch
is pushed.
Note) Pushing the switch again when the required louver direc-
tion has been reached will stop the louver.
Adjustment of air flow direction rightwards/leftwards
To change the air outlet direction to the right or left side, set the vertical
flap located behind the horizontal flap to the desired direction.
Setup of air direction and swinging
1H series: Refer to the description of "2-way Air Discharge Cassette
Type".
2H series: Refer to the description of "Under Ceiling Type, 1-way Air
Discharge Cassette Type (2SH Series)".
• If cooling operation is performed with a downwards discharge,
dew may form on surface of the cabinet or the horizontal flap
resulting in possible dripping.
• If heating operation is performed with a horizontal discharge,
the room temperature may not be equal i.e. there may be a
large variance between one side of the room with the other.
REQUIREMENT
SWING/FIX
button on the remote controller.
INFORMATION
13