9. Troubleshooting

Engine does not start:
Nein
Enough fuel in the tank?
Start switch set to "ON"?
Fuel cock open?
Enough engine oil filled in?
Is there a spark at the spark plug?
!Warning!
Ensure that there is no spilled fuel in the
vicinity of the spark plug. Spilled fuel can
ignite.
Use insulated pliers or at least gloves to
position the spark plug in order to protect
yourself from electric shock.
Fuel flow to the carburettor?
If the engine still does not start,
take the generator to an author-
ised workshop.
No electrical power at the connections:
Main switch set to "ON"?
Yes
34
Yes
Yes
Yes
Observe low oil
No
safeguard
Yes
Replace the spark
No
plug
Checking the spark plug
1. Remove the spark plug connector and clean the spark
plug of dirt.
2. Remove the spark plug and fit the spark plug connector
to the spark plug again.
3. Place the earth electrode against the cylinder head.
4. Pull the pull-cord starter. Sparks should jump between
the electrodes.
Yes
Checking the fuel flow
Yes
1. Set the fuel cock to "Closed" and loosen the drain screw
on the carburettor reservoir (after placing a suitable con-
tainer underneath).
2. As soon as the petrol cock is turned to "Open", fuel
should flow.
Translation of the original operating instructions
No
Fill up the petrol tank
No
Set the starter switch to "ON"
No
Set the fuel cock to "On"
Top up with the recommended engine
oil
If the device still does not function with newly in-
serted spark plug (because there is no spark at
the spark plug), take it to an authorised workshop
Take the device to an authorised workshop to
No
have the fuel system cleaned.
No
Set the main switch to "ON"
• Take the device to an authorised work-
shop for repair.
• Replace the device.