Kozy Heat Fireplaces KZK-045 Manuel page 12

Kit komfort zone pour utiliser bellingham 44, bhm-44
Masquer les pouces Voir aussi pour KZK-045:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2.2 Combustible Wall Finish
Figure 3.5 shows installation of combustible wall finish up to 1"
thick. This combustible material goes on any required non-
combustible materials as shown in Figure 3.1 on page 10.
This 1" (25mm) combustible material is able to go down to the
fireplace finishing edge.
See Figure 3.3 on page 11 for up to 1" (25mm) thick
combustible material installation around the discharge trim of
the KZK air discharge opening.
Non-combustible zone
Combustible wall nisihng
up to 1" (25mm) thick
may be installed up to
the top nishing edge
and the bottom of the
air discharge opening
Non-combustible
material
Figure 3.5, #KZK-045 Combustible Wall Finish
12 FACING AND FINISHING
Finishing edge
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Komfort Zone Kit #KZK-045 R.1