Emerson LURAY ECO CF860B000 Mode D'emploi page 22

Ventilateur de plafond de 60 po pour environnement humide
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Wall Control Installation
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire Is
required (See Figure 36).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
8.8
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan wall control into the outlet box.
Screw wall control into wall box using the supplied
screws. Leave wall control in "OFF" mode until fan
installation is completed.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
The wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the wall
control (Figure 36).
Next, install the other wall control into the wall box
containing the load wire. Connect the black wire of the
wall control to the traveler wire(s) already connected to
the black wire (in the other wall box). Secure with wire
connectors supplied.
(Continued)
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
HOT
BLK
3-WAY WIRING DIAGRAM: RETROFIT
HOT
BLK
BLK
FAN/LIGHT
WALL
CONTROL
Figure 36
Connect one black wire of the wall control to the "load"
(black) wire and secure with wire connector supplied.
Connect one black wire of the wall control to both
remaining traveler wires in the wall box and secure with
wire connector supplied.
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
22
EXISTING
WALL CONTROL
TRAVELER WIRES
BLK
BLK
FAN/LIGHT
TRAVELER
WALL
WIRES
CONTROL
WARNING
LOAD
LOAD

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Luray eco cf860pt00Luray eco cf860ww00

Table des Matières