1. Mount the BMS preferably on a vertical surface, for optimal
Mount the BMS preferably on a vertical surface, for optimal
cooling.
2. Determine the rating of fuse AB (see figure and table 1)
The fuse on input AB doubles as a shunt. The BMS will limit the
input current according to the rating of this fuse. For fuse
and corresponding current limit please see table
Choosing the right fuse will prevent overheating of the alternator
Choosing the right fuse will prevent overheating of the alternator
and/or DC cabling.
3. Determine the rating of fuse LB (see figure).
This fuse should be rated in accordance with the expected load
This fuse should be rated in accordance with the expected load
current and the cross section of the cabling to the load.
current and the cross section of the cabling to the load.
4. Disconnect the cabling from the plus pole of the starter battery.
Disconnect the cabling from the plus pole of the starter battery.
5. Pull off the REMOTE on/off connector to prevent unwanted
off connector to prevent unwanted
switching of the BMS.
6. Install and connect all electrical cabling and fuses AB,
leave the plus poles of the Li-ion batteries and star
disconnected.
7. Daisy-chain the battery control cables between the
and connect to the BMS.
8. Connect the plus cabling to the Li-ion batteries and
battery.
9. Reinsert the REMOTE on/off connector on the BMS.
The BMS is now ready for use.
Notes:
a) A battery charger can be connected to input AB instea
A battery charger can be connected to input AB instead of the
alternator.
b) The Li-ion batteries can be charged as well as discharged t
charged as well as discharged through
input/output LB.
c) When a load with a large electrolytic capacitor bank
When a load with a large electrolytic capacitor bank (such as an
inverter or inverter/charger rated at 1200VA or more) is connected
inverter or inverter/charger rated at 1200VA or more)
to LB, the BMS will limit its average output current during start
to approximately 80A. Therefore the capacity to simultaneously
. Therefore the capacity to simultaneously
start-up other DC loads is limited to 80A. Once the capacitor bank
up other DC loads is limited to 80A. Once the capacitor bank
is fully charged, the current limit increases to 400A.
is fully charged, the current limit increases to 400A.
If the required charge current
(input AB) is less than 40 A,
please use this ATO fuse holder
AB
Phone: (+31) (0)36 535 97 00 / Fax:
and table 1).
shunt. The BMS will limit the
. For fuse ratings
1.
and fuses AB, LB, but
ion batteries and starter battery
the Li-ion batteries
and the starter
on the BMS.
output current during start-up
Up to ten 12,8V LFP batteries
Up to ten 12,8V LFP batteries
can be connected in parallel
can be connected in parallel
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
ax: (+31) (0)36 535 97 40 /
BMS 12/200 specification
specification
Maximum number of 12,8V batteries
Maximum charge current, Power Port AB
Maximum charge current, Power Port AB
Maximum charge current, Power Port LB
Maximum charge current, Power Port LB
Maximum continuous discharge current, LB
Maximum continuous discharge current, LB
Peak discharge current, LB (short circuit proof)
B (short circuit proof)
Approximate cut-off voltage
GENERAL
No load current when operating
Current consumption when switched off
Current consumption when switched off
Current consumption after battery discharge
Current consumption after battery discharge
cut-off due to low cell voltage
Operating temperature range
Humidity, maximum
Humidity, average
Protection, electronics
DC connection AB, LB and battery minus
DC connection AB, LB and battery minus
DC connection battery plus
LED's
Battery being charged through Power Port AB
Battery being charged through Power Port AB
Battery being charged through Power Port LB
ery being charged through Power Port LB
Power port LB active
Over temperature
ENCLOSURE
Weight (kg)
Dimensions (hxwxd in mm)
STANDARDS
Emission
Immunity
Automotive Directive
Fuse AB
100 A
80 A
60 A
2 x 30 A
2 x 20 A
2 x 15 A
2 x 10 A
2 x 7,5 A
Table 1
LB
Isolated Orion DC-DC converter
DC converter
needed for DC loads with minus
th minus
connected to chassis
www.victronenergy.com
/ e-mail: s
Revision : Rev 02
Date
: 31-05-2013
10
80A @ 40°C
200A @ 40°C
200A @ 40°C
400A
11V
10mA
5mA
3mA
-40 to +60°C
100%
95%
IP65
M8
Faston female
6.3 mm
green
green
green
red
1,8
65 x 120 x 260
EN 50081-1
EN 50082-1
2004/104/EC
Max. charge current
Max. charge current
90 A
70 A
40 A
35 A
25 A
20 A
18 A
12 A
il: sales@victronenergy.com

Publicité

loading

Sommaire des Matières pour Victron energy BMS12/200

  • Page 1 Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands...
  • Page 2 Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands...
  • Page 3 être connectées en parallèle peuvent être connectées en parallèle Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands...
  • Page 4 Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands...
  • Page 5 Batterien parallel schalten. Batterien parallel schalten. Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands...