OPERATION
Controls
The hood is operated using the (5) push buttons located
on the underside of the
hood. Fig. 1.
FIG. 1
Ten Minute Delay
Press Speed 1, Speed 2, or Speed 3 for two seconds when the blower is running at
the selected speed. The LED below the button will start blinking to display the delay
function. After ten minutes the blower will automatically turn off. If you change the
speed while the timer is running, the function will not deactivate. To deactivate the
function, press the button with the blinking LED for two seconds. Note: The delay
is not available for Speed 4.
Filter Alarm
After 30 hours of blower operation, the filter alarm is activated and all of the LED
indicators will turn on. The alarm is activated when the motor is off and the LEDs will
remain on for 30 minutes. To deactivate the alarm, press any of the control buttons
for two seconds while the LEDs are on.
After 120 hours of blower operation the charcoal filter alarm is activated and all of
the LED indicators will blink. The alarm is activated when the motor is off and the
LEDs will remain on for 30 minutes. To deactivate the alarm, press any of the control
buttons for two seconds while the LEDs are on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY™ thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.