3. LANGUAGE SETTING
It is suggested to select the language before any other operations
Press key P3 for 2 seconds. Confirm pressing key P2.
4. PROGRAMMING MENU
This procedure must be carried out ONLY by the installer and ONLY during the installation of the system.
WARNING: the motor must be still, preferably in closed position, in order to access the programming menu!
4.1 Activation and selection of the programming menus
The control board J-INV 3P is equipped with THREE user menus (MENU A, MENU B, MENU C), by which it is possible to regulate, program and modify all featureal parameters. Follow the
indications on the display during the programming phases.
MENU A - allows to activate the optional feature and to select the intervention modalities of the security systems.
MENU B - it is dedicated to the learning of the runs, to the operations related to the manual movement and to the regulation of the control parameters of the motor
MENU C - menu for auxiliary configurations for user's
1
Stop the motor and get in safety conditions
Press and keep pressed key P1 for 2 seconds in order to activate MENU A
2
Press and keep pressed key P2 for 2 seconds in order to activate MENU B
Press and keep pressed key P3 for 2 seconds in order to activate MENU C
3
Select an entry of the menu (see following table); shortly press key P3 to scroll down
to the following index, or key P1 to go back to the previous menu
4
Confirm the entry selected by pressing key P2
Modify the status of the parameter by following the indications written in
5
the second line of the display by using keys P1 e P3.
6
Confirm the setting selected by pressing key P2
It is possible to modify other parameters (go back to point 3) or to exit the
7
programming menu by selecting the option EXIT (confirm by pressing key P2)
AUTOMATIC EXIT FROM THE MENU: the menu exits automatically in case of long inactivity (longer than 15 seconds)
Some parts of the control board are subject to dangerous voltages!
Pay attention during the phase of manual accessing to the control board
27
Select the language by pressing either P1 or P3. Confirm pressing key P2
The display must not show any indications
8888888888888888
8888888888888888
8888888888888888
8888888888888888
8888888888888888
8888888888888888
The display shows the entry selected.
The first line of the display shows the present setting for the feature
selected.
The second line of the display shows the possible modification settings
according to the parameter selected (see specific paragraphs)
The first line of the display shows the present setting for the feature
selected.
The second line of the display shows the possible modification settings
according to the parameter selected (see specific paragraphs)
The display indicates the correct storage of data and then shows the entry
selected
Exit from menu is confirmed by the absence of indications on the
display
G
B
The display shows the first
entry available