G
B
10
11
12
13
14
15
16
CLOSE COMMAND
Connect the CLOSE button between the clamps 3 and 12 of
the control board.
ATTENTION: leave it open if not used
ENCODER INPUT
Connect the SIGNAL cable of the encoder to the clamp 13
of the control board.
Connect the GND cable of the encoder to the clamp 14 of
the control board.
Connect the cable +Vdc of the encoder to the clamp 15 of
the control board.
ATTENTION: leave it open if not used
PHOTOCELLS POWER SUPPLY
Connect the clamp 16 of the control board to the + power
supply clamp of the photocells receiver.
Connect the clamp 17 of the control board to the - power
supply clamp of the photocells receiver and transmitter.
Connect the clamp 18 of the control board to the + power
supply clamp of the photocells transmitter.
ACCESSORIES OUTPUTS
Accessories output 24 Vac 3W.
MOTOR OUTPUT
Connect the phases of the motor to the clamps 21, 22, 23,
an the ground to the clamps 24 or 25.
ATTENTION !! THE MOTOR SHOULD BE DELTA
CONNECTED
For the connection of the motor we recom-mend to use a
screened cables 3 poles + earth 1.5 mm2 (type FD781CY)
POWER SUPPLY
Connect the power supply cable to the clamps 26 and 27,
connect the ground to one of the clamps PE 28, 29 or 30.
COURTESY LIGHT
Connect the courtesy light to the clamps 33 and 34, 230Vac
100W MAX.
FLASHING LIGHT
Connect the flashing light to the clamps 31 and 32
26
The activation/deactivation of the encoder feature is
controlled in the MENU A
For the connection of the possible encoder we
recommend to use a screened cable 3 x 0,75mm2 (type
OLFLEX-110CH)
MENU A can enable photocells test.
ATTENTION: the control board gives a voltage of 24 Vdc and
can supply a maximum power of 3W.
For the safety edges test connect the test device of the safety
edge on the power supply pins of the TX (test activated wiht
low logic signal 0Vdc).
Please refer to the manual of the safety edge.
Before activating the automation make sure that all the safey
devices are correctly cabled and featureing.
Refer to the preliminary checkings section of chap.4
!! Risk of electric shock !!
Do not connect the card directly to the electric network. Put a
device which can ensure the disconnection of each pole from
the power supply of the control board
Use a cable with correct section according to the current
absorbed by the motor.
It is possible to light up the action area of the automatism
during each motion.
The featureing of the auxiliary light is controlled by the MENU
A.
Use a flashing light without self flashing card 230Vac 60W
MAX