It is FUNDAMENTAL to connect the electric EARTH to the control board
and the motor in order to obtain the correct operation of the control
board and photocells !
WARNING!! DELTA CONNECTION OF THE MOTOR IS REQUIRED.
For the connection of the motor we recommend to use a screened cables 3 poles +
earth 1.5 mm
2
(type FD781CY)
2. CONNECTIONS
1
2
3
4
5
6
7
8
9
NOTE: EDGE, PHOTO and STOP inputs (NC). If they are not used, must
be excluded.
ATTENTION: before starting the automation, make sure that the safety
devices installed are working correctly.
ANTENNA INPUT
Connect the signal cable of the antenna to the clamp 1 of
the control board.
Connect the ground of the antenna to the clamp 2 of the
control board.
STEP BY STEP COMMAND
Connect the STEP-BY-STEP BUTTON (S.S.) between the
clamps 3 and 4.
ATTENTION: leave it open if not used.
PHOTOCELL INPUT
Connect the NORMALLY CLOSED contact of the photocell
(PHOTO) between the clamps 3 and 5 of the control board.
ATTENTION: jumper the inputs if not used.
STOP COMMAND
Connect the NORMALLY CLOSED contact of the STOP
button between the clamps 3 and 6 of the control board.
ATTENTION: jumper the inputs if not used.
SAFETY EDGE INPUT
Connect the contact NORMALLY CLOSED of the SAFETY
EDGE between the clamps 3 and 7 of the control board.
ATTENTION: jumper the inputs if not used.
CLOSING LIMIT SWITCH INPUT
Connect the NORMALLY CLOSED contact of the CLOSING
LIMIT SWITCH (L.S.CL.) between the clamps 3 and 8 of the
control board.
OPENING LIMIT SWITCH INPUT
Connect the NORMALLY CLOSED contact of the OPENING
LIMIT SWITCH (L.S.CL.) between the clamps 3 and 9 of the
control board.
PEDESTRIAN OPENING COMMAND
Connect the PEDESTRIAN OPENING button (PED.) between
the clamps 3 and 10 of the control board.
ATTENTION: leave it open if not used
OPEN COMMAND
Connect the OPEN button between the clamps 3 and 11 of
the control board.
ATTENTION: leave it open if not used
25
The presence of the metallic parts or humidity in the walls
could have negative influences on the range of the system.
We suggest therefore to not place the receiving antenna and/
or transmitters near big metallic objects, near the floor or on
the ground.
Under the dead man mode the STEP BY STEP BUTTON
operates as OPEN.
The operation of the photocells can be modified in the MENU
A.
Before activating the motor, make sure that limit switches
are correctly adjusted.
Before activating the motor, make sure that limit switches
are correctly adjusted.
When dead man mode is enabled, the Pedestrian opening
button operates as CLOSE.