Putting into service and Operation:
The points for putting into service and operation of the centraFILL-deluxe with Combi filler unit
adapter are identical with those for the centraFILL-deluxe up as far as the following point.
-
The pump can now be pushed through the clamp and secured with the clamping bolt.
-
Fit the ZSA hydraulic coupling onto the plug of the central lubrication system.
-
The centraFILL is now ready for use.
-
When filling a central lubrication system connect the ZSA hydraulic coupling to the central
lubrication system and open the isolating ball tap on the Combi filler unit adapter. You will get the
right connection plug as an accessory under Order Ref. No.. 33 902 28.
-
When filling lubricating equipment close the ball tap on the Combi filler unit adapter. The charging
nipple of the lubricating equipment must be pressed firmly into the charging socket of the Combi
filler unit adapter whilst filling is taking place. The charging socket has a check valve which only
opens when the charging nipple is pushed in.
Maintenance:
Make a regular check on the pressurised components of the pump.
Replace defective or damaged hoses with genuine spares without delay.
Damaged hoses can cause serious injury by sudden failure.
Safety Instructions:
Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the equipment. Non-compliance with the safety instructions can lead to the
loss of any claims for damages. The operator of the equipment must ensure that the
contents of the Operating Instructions, particularly the Safety Instructions are known to the
operating personal..
Make a regular check on the pressurised components of the pump.
-
Damaged hoses can cause serious injury by sudden failure.
-
For this reason, replace defective or damaged hose runs and nozzle tubes with genuine spares
-
immediately.
Only use original accessories. No liability can be accepted for accidents caused by components
-
from other sources.
Never use force on the pumping lever of the grease gun or extend it with unapproved items such
-
as pipes etc. This could generate unacceptably high pressures.
The operational safety of the equipment is only guaranteed if used in accordance with the
-
directions.
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
-
who have acquainted themselves with the subject by studying the operating instructions..
Warranty:
If the operating instructions are complied with and the equipment used in accordance with the
directions, we accept liability within the bounds of the statutory warranty obligation (see our conditions
of delivery).
When making warranty claims always attach the invoice from your dealer, giving the date of purchase.
Your contribution to protecting the environment:
The pertinent regulations for the registration, setting up and operation of equipment for dealing with
materials hazardous to water must always be complied with by the user.