Putting into service and Operation:
-
Open the grease container and push the follower piston onto the grease.
-
Place the centralising cover onto the grease container.
-
Loosen all 3 wing bolts and push the centralising slides inwards (towards the centre).
-
Push the pegs to move the retainer hooks outwards as far as they will go.
-
Now place the centralising lid onto the grease container so that the retainer hooks are on the
outside and the centralising slides are on the inside of the grease container.
-
Push the wing bolts to move the centralising slides outwards as far as they will go
(the lid will automatically centralise itself on the grease container)
-
Keeping the wing bolt pushed outwards, push the pegs to move the retainer hooks inwards as far
as they will go. Tighten the wing bolt.
-
Secure the remaining two wing bolts and pegs as described previously.
N.B. Check that the centralising lid is seated firmly on the grease container.
-
The pump can now be pushed through the clamp and locked in place with the clamping screw.
-
Push the ZSA hydraulic coupling onto the
plug of the central lubrication unit.
-
The centraFILL is now ready to use.
Description:
The centraFILL with Combi filler unit adapter is suitable for the charging of grease reservoirs on
central lubrication systems and for filling lubricating equipment fitted with a charging nipple to
DIN 1283 Ø 9 mm.
Commercial greases up to NLGI Class 2 can be pumped by the unit.
We expressly exclude any other use.
Delivery specification:
Pumping gear with 2 m PVC outlet hose and ZSA hydraulic coupling.
Combi filler unit adapter, centralising lid, grease follower piston.
Technical Data:
Delivery rate ca. 45 ccm / stroke
Delivery pressure ca. 30 bar
(can be varied in line with customer's wishes)
Combi filler unit adapter
With isolating ball tap
2 m PVC hose,DN16
ZSA hydraulic
coupling
-
The ecoFILL is now ready to use.
-
Push the charging nipple of the lubrication unit
onto the filler pipe of the filler unit. The filler pipe
has a check valve. During the filling process the
grease automatically pushes back the sealing
collar in the grease container. The piston rod of
the grease container must be pushed fully in
before filling takes place. If increased resistance
is felt at the hand lever of the filler unit, the filling
process is finished.
Clamp
Clamping bolt
Centralising slide
with wing bolt
Retainer hook with peg
Centralising lid
cpl. When ordering
give outside
diameter of tub
Grease follower
piston.
When ordering
give inside
diameter of tub
9