Télécharger Imprimer la page

EHEIM eXperience 350 Mode D'emploi page 12

Masquer les pouces Voir aussi pour eXperience 350:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Check to ensure that the sealing gasket on the pump head
of the filter is not soiled and that it is properly placed into
its groove.
Place the pump head onto the filter canister so that the in-
put connector of the pump head is lined up with the input
guide of the media containers. Close all four EZ clips.
ATTENTION:
Before the integrated dou-
ble tap connector is inserted
into the pump head of the fil-
ter, examine all three o-rings
for damage and correct fit-
ting. Lightly grease the o-
rings with Vaseline to help
installation.
Insert the integrated double tap connector with the locking
clamp in an upright position into the opening on the pump
head. To fasten the locking clamp into its sealed position push
the handle downwards.
Tubing installation
Shut off the integrated double tap connector by shifting the
two levers to the OFF position. Push the enclosed tubing onto
the intake and output openings of the integrated dou-ble tap
connector as far as they will go. Since this can be a relatively
difficult task, soak the hoses in warm water beforehand to
make them softer.
It is very important to use original EHEIM  hoses only.
Place the two-part hose clamp around the installed hoses,
hang into the proper position and clip into place.
Place the now ready-to-use filter into the lower cabinet of your
aquarium stand and observe the prescribed installation height:
between water surface and base of filter there should be max.
180 cm (5'11'') in order to attain optimum functioning.
max. 180 cm
8

Publicité

loading

Ce manuel est également adapté pour:

2426