6. Output data format

The section covers the exporting of data form the scale to an external device (e.g. PC) using a USB compliant signal.
Conguration
Communications standard
Communications method
Signal speed
Data bit length
Parity
Stop bit
Terminator
Note:
• USB connector (B Type 4 pin female) is located on the side of the WB 8000RW.
• Please provide your own cable as necessary as none are included.USB cable: A Type 4 pin (male) B Type 4 pin (male)
• You must install the necessary driver onto your PC, available download from http://www.tanita.com.
Output
Name of item
Header
Control data
{ 0
Fix to 16
Control data
˜0
Fix to 1
Model
MO
"WB-8000"
Height
Hm
xxx.x
Weight
Wk
xxx.x
BMI
MI
xxx.x
Checksum
CS
xx
Note:
• The data is divided with commas (,) for each data.
• The terminator (end of the data) is CR (ASCII code 0DH), LF (ASCII code 0AH).
• The control data for the items 1 – 4 are for expansion. They are not used presently so the receiving side can ignore them.
• Because of its specifications, the scale will output an irrelevant signal approximately 0.1 second after data output. Make sure you ignore this
signal and do not import it.
[Output example]
• When the WB-8000RW's Mode Selection Switch is set to ON, both wireless output and USB output
can be used. USB transmission will be set to output-only, and when the display is set your weight
and BMI will be automatically output. The LED will be green.
• When the WB-8000RW's Mode Selection Switch is set to USB ONLY, only USB output can be used.
USB transmission will be possible in both directions (input and output). The LED will be blue.
8
USB
Asynchronous transaction
9600 baud
8 bits
None
1 bit
CR+LF
Pattern
Output data (ASCII code)
BMI mode
Weight mode
2 Bytes fixed
1 Byte fixed
9 Byte fixed
4 – 5 bytes
3 – 5 bytes
3 – 5 bytes
2 Bytes fixed
<Data Format when Mode Selection Switch is Set to USB ONLY>
• This mode is used to control the WB-8000RW via computer.
• This scale is not capable of receiving instructions from an external device. When using the ON mode.