Positioning the Monitor
Place the measuring platform on a hard, flat surface where there is minimal
vibration to ensure safe and accurate measurement.
Note: To avoid possible injury, do not step on the edge of the platform.
Handling Tips
This monitor is a precision instrument utilizing state-of-the-art technology.
To keep the unit in the best condition, follow these instructions carefully:
・Do not attempt to disassemble the measuring platform.
・Store the unit horizontally, and place it so that the buttons will not be pressed accidentally.
・Avoid excessive impact or vibration to the unit.
・Place the unit in an area free from direct sunlight, heating equipment,
high humidity, or extreme temperature change.
・Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep
them shiny; avoid soaps.
・Do not step on the platform when wet.
・Do not drop any objects onto the platform.

GETTING ACCURATE READINGS

To ensure accuracy, readings should be taken without clothing and under consistent
conditions of hydration. If you do not undress, always remove your socks or
stockings,and be sure the soles of your feet are clean before stepping on the
measuring platform.Be sure that your heels are correctly aligned with the
electrodes on the measuring platform. Don't worry if your feet appear too large for the
unit -accurate readings can still be obtained if your toes overhang the platform.
It is best to take readings at the same time of day. Try to wait about three
hours after rising, eating, or hard exercise before taking measurements.
Heels centered on
Toes may overhang
While readings taken under other conditions may not have the same
electrodes
measuring platform
absolute values, they are accurate for determining the percentage of change
as long as the readings are taken in a consistent manner. To monitor
Note: An accurate reading will not be possible if
the soles of your feet are not clean, or if your
progress, compare weight and body fat percentage taken under the same
knees are bent or you are in a sitting position.
conditions over a period of time.

AUTOMATIC SHUT-DOWN FUNCTION

The automatic shut-down function shuts off the power automatically in the following cases:
・If you interrupt the measurement process. The power will shut down automatically within 10 to 20 seconds,
・depending upon the type of operation.
・If an extreme weight is applied to the platform.
・During programming, if you do not touch any of the keys or buttons within 60 seconds.*
・After you have completed the measuring process.
*Note: If the power shuts off automatically, repeat the steps from "Setting and Storing Personal Data in Memory" (p.3).

SWITCHING THE WEIGHT MODE

You can switch the unit indication by using the switch on the back of the scale as shown in the figure.
Note: If weight mode is set to pounds or stone-pounds, the height programming mode will be automatically set to feet
and inches.
Similarly, if kilograms is selected, height will be automatically set to centimetres.
2
Note: For use only with models containing the weight mode switch

SETTING AND STORING PERSONAL DATA IN MEMORY

You will receive readings only if data has been programmed into one of the personal data memories or the Guest mode.
The monitor can store personal details for up to 4 people.
1. Turn on the Power
Press the Set button to turn on the unit (once programmed, tapping a Personal Key turns
on the unit.) The unit will beep to confirm activation, the Personal Key numbers (1,2,3,4)
will be displayed, and the display will flash.
Note: If you don't operate the unit for sixty seconds after the unit has been turned on, the unit
will turn off automatically.
Note: If you make a mistake or want to turn the unit off before you have finished programming
it, press the Weight-Only Key (
) to force quit.
2. Select a Personal Key Number
Press the Up/Down buttons to select a Personal Key. Once you reach the
Personal Key number you wish to use, press the Set button. The unit will
beep once to confirm.
3. Set Age
The display defaults to Age 30 (range of user age is between 7-99). An
arrow icon appears on the lower left side to indicate Age setting. Use the
Up/Down buttons to scroll through numbers. When you reach your age,
press the Set button. The unit will beep once to confirm.
4. Select Female or Male
Use the Up/Down buttons to scroll through Female (
and Male/Athlete settings, then press the Set button. The unit will beep once to confirm.
5. Specify the Height
The display defaults to 5' 7.0" (170cm) (range of user is from 3' 4.0"–7' 3.0" or
100cm – 220cm). Use the Up/Down buttons to specify Height and
then press the Set button. The unit will beep once to confirm.
6. Select Activity Level
T
o use the DCI (Daily Calorie Intake) feature properly, you need to set the Activity Level.
Use the Up button to specify Activity Level. Press the Set button to confirm.
Level 1 = Inactive lifestyles (little or no exercise)
Level 2 = Moderately active lifestyles (occasional, low intensity exercise)
Level 3 = Adult involved in intense physical activity (see p.1. for Tanita's definition
of Athlete)
Note : If you select the Athlete Mode, it will automatically set the Activity Level to Level 3.
The unit will beep twice and the display will flash all data (Male/Female, Age, Height, Activity
Level, etc.) three times to confirm the programming. The power will then shut down
automatically.