OPERATING INSTRUCTIONS
2. FAN RUNNING
1). In fan mode, the display panel displays the room temperature, and both fan speed and air flow direction
are adjustable.
2). The compressor does not operate during FAN mode.
3. ENERGY SAVER
1). This function is only available during cool running and the fan speed can be adjusted.
2). During ENERGY SAVER fan motor runs when the compressor runs, fan motor stops when the
compressor stops.
3). Avoiding consuming electrical energy when the fan motor works independently.
4.PROMTING FOR CLEANING THE AIR FILTER
After the air conditioner has run for200 hours and when it is turned off, the display panel will
flickeringly
display"CF" to remind you of cleaning the air filter.
5. SLEEP FUNCTION
Press the sleep button on the remote controller to start sleep function and press it again to stop sleep
function . During sleep mode, only the relative function indicator lamp lights.
Notice: Press fan speed button during sleep mode, the air conditioner will stop sleep function.
During cooling mode, the set temperature will increase 2
will increase 2
°F(1 )
within two hours after setting sleep mode), then the air conditioner will work at this temperature all along.
During SLEEP mode, FAN SPEED will be "LOW".
14
14
once more in the next one hour (that means the set temperature increases 4
°F(1 )
one hour after setting SLEEP mode, and
°F(2 )