• Cracks due to the insulation ageing.
Such damaged electrical connection ca-
bles must not be used and are life-threat-
ening due to the insulation damage.
Check the electrical connection cables
for damage regularly. Make sure that
the connection cable does not hang on
the power network during the inspection.
Electrical connection cables must comply
with the applicable VDE and DIN provi-
sions. Only use connection cables with
the marking „H05RN-F".
10. Cleaning, maintenance
and storage
Cleaning
Attention!
Always unplug the power cord before
cleaning.
General cleaning instructions
• In case of transport for utilization in
different locations, the pump must be
cleaned with clear water after every use.
• In case of stationary installation, the
function of the float switch (3) is to be
checked regularly (at the latest every
three months).
• With a water jet, remove fluff and fibrous
particles which are possibly present in
the pump casing
• Regularly remove sludge from the pit
base (at the latest every 3 months) and
also clean the shaft walls
• Clean precipitation from the float switch
with clear water,
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
• In the case of a long period of non-use,
the pump must be thoroughly cleaned
after the last use and before the new
use, since difficulties in start-up can
arise due to precipitation and residues.
Cleaning the impeller wheel
If the impeller wheel is dirty or blocked,
you can clean it via the pump connection
(7) or by removing the floor plate (8):
1. Screw the pump connection angle (5)
off the pump connection (7).
2. Remove the screws at the bottom of
the pump housing and take off the floor
plate (8).
3. Remove the screws at the bottom of the
foot part (9) and take off the foot part
(9).
4. Clean the impeller wheel with clear wa-
ter.
5. The re-assembly takes place in reverse
order.
Store the device and its accessories in a
dark, dry and frost-proof place that is in-
accessible to children. The optimum stor-
age temperature is between 5 and 30˚C.
Cover the electrical tool in order to pro-
tect it from dust and moisture.Store the
operating manual with the electrical tool.
Maintenance
The pump is largely maintenance-free.
However, we recommend regular inspec-
tions and care for a long service life.
Connections and repairs
Connections and repairs of electrical
equipment may only be carried out by an
electrician.
GB | 27