Electrical Connection; Cleaning And Maintenance - Scheppach GP1000 Jet LCD Traduction Des Instructions D'origine

Masquer les pouces Voir aussi pour GP1000 Jet LCD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
7.
Now, repeat the steps 3 – 5, to set the power-on
time and to confirm it.
8.
By pressing the "Check button" (6) again, the dis-
play will show the "Time Off" mode. In this mode
you determine the time at which the pump should
switch off (fig. 11).
9.
Now, repeat the steps 3 – 5, to set the automatic
power-off time and to confirm it.
10. The switch-on and switch-off times then appear in
the display "Time On / Time Off" (fig. 12). It is not
necessary to press the "Check button" (6) again.
11. After a brief waiting time, "Time Mode" (fig. 13) ap-
pears on the display showing the time set.
10.5 "Ever On Mode" continuous operation (fig. 14)
(not recommended)
The pump can also be operated in continuous mode.
In this mode there is no automatic safety switch and
therefore the pump may only be operated under con-
tinuous observation!
1.
Connect the pump to the power supply. The dis-
play shows "Power on" (fig. 3).
2.
Press the "Mode button" (4) several times until
"Ever On Mode" is displayed (fig. 14).
Attention:The pump immediately starts. Please
ensure that the product is completely assembled.
3.
By pressing the "Mode button" (4) again, the pump
switches off. The display shows "Power on" (fig.
3).

11. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
26 | GB
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
Mains power connection and extension leads must be
3-core = P + N + SL. - (1/N/PE).
Extension cables up to 25m long must have a
cross-section of 1.5 mm². The mains power connection
must be protected with a max. 16 A fuse.

12. Cleaning and maintenance

m
ATTENTION!
Only carry out maintenance, cleaning and adjustment
work when the mains plug is pulled out.
We recommend that you clean the product directly af-
ter every use.
Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic parts
of the product. Make sure that no water can penetrate
the motor.
• We recommend regular inspections and care for a
long service life.
• Before extended periods of inactivity or through
the winter, the pump should be thoroughly flushed
through with water, emptied completely and then
stored dry.
• To empty the pump housing, loosen the water drain
screw (9) and tilt the pump slightly.
www.scheppach.com