• Places where the connection cables
have been cut due to being driven over.
• Insulation damage due to being ripped
out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection ca-
bles must not be used and are life-threat-
ening due to the insulation damage.
Check the electrical connection cables
for damage regularly. Make sure that the
connection cable does not hang on the
power network during the inspection.
Electrical connection cables must comply
with the applicable VDE and DIN provi-
sions. Only use connection cables with
the marking „H05RN-F".
The printing of the type designation on
the connection cable is mandatory.
For single-phase AC motors, we recom-
mend a fuse rating of 16A (C) or 16A (K)
for machines with a high starting current
(starting from 3000 watts)!
AC motor 230 V~/ 50 Hz
Mains voltage 230 V~ / 50 Hz.
The mains connection and the extension
cable have to be three-core cables = P +
N + SL. - (1/N/PE).
Extension cables up tp 25m long must
have a minimum cross-section of 1.5
mm². Mains fuse protection is 16 A max-
imum.
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
10. Cleaning and Maintenance
Attention!
Only carry out maintenance, cleaning and
adjustment work when the mains plug is
pulled out. We recommend that you clean
the device directly after every use.
Clean the device at regular intervals using
a damp cloth and a little soft soap.
Do not use any cleaning products or sol-
vents - they could attack the plastic parts
of the universal machine stand. Make
sure that no water can penetrate the de-
vice interior.
• The pump is largely maintenance-free.
However, for a long service life, we rec-
ommend regular checking and care.
• Before extended periods of inactivity or
through the winter, the pump should be
thoroughly flushed through with water,
emptied completely and then stored dry.
• To empty the pump housing, loosen the
water drain screw (9) and tilt the pump
slightly.
• If there is a risk of frost the pump must
be completely emptied.
• After longer periods of storage check the
pump by switching on/off briefly in order
to check that the rotor turns normally.
• In the event of the pump being jammed
connect the pressure line to the wa-
ter supply line and remove the suc-
tion hose. Open the water supply line.
Switch the pump on for ca. two seconds
several times. This method rectifies
blockages in most cases.
• To clean the pre-filter (12), unscrew the
pre-filter cap (11) and remove the filter
unit. Clean the pre-filter with warm wa-
ter.
GB | 27