6. Technical data
Dimensions L x
B x H
Mains connection
Power rating
Max. delivery rate
Max. delivery
head
Immersion Depth
max.
Hose Connection
Max. water
temperature
Protection type
Particle size max.
Weight
Subject to technical changes!
7. Unpacking
Open the packaging and remove the de-
vice carefully.
Remove the packaging material as well
as the packaging and transport bracing
(if available). Check that the delivery is
complete.
Check the device and accessory parts for
transport damage. In case of complaints
the dealer must be informed immediate-
ly. Subsequent complaints will not be ac-
cepted.
If possible, store the packaging until the
warranty period has expired.
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
154 x 154 x 327
mm
220 - 240V~
50 Hz
750 W
14000 l/h
9,5 m
7 m
G1 ¼" = 41,9 mm
35 mm
G1" = 33,2 mm
25 mm
35°C
IPX8
35 mm
4,7 kg
Read the operating manual to make your-
self familiar with the device prior to using
it.
Only use original parts for accessories as
well as for wearing and spare parts. Spare
parts are available from your specialized
dealer. Specify our part numbers as well
as the type and year of construction of the
device in your orders.
m ATTENTION
The device and packaging materials
are not toys! Children must not be al-
lowed to play with plastic bags, film
and small parts! There is a risk of
swallowing and suffocation!
8. Attachment / Before start-
ing the equipment
Connecting the line (fig. 3)
The pump is installed either with a fixed
pipeline or with a flexible hose line.
• Screw the pump connection angle (5)
onto the pump connection (7).
• Screw the connecting branch for hose
(6) onto the pump connection angle (5).
• Put the hose over the connecting
branch for hose (6) and fasten it with a
hose clamp. Alternatively, use a screw
connection on the pump connection an-
gle (5) or on the connecting branch for
hose (6).
• Check that the pump is standing firmly on
the bottom of the shaft or hung up safely.
• Check whether the pressure line has
been attached correctly and the un-
used pump outlet is fully closed.
• Avoid that the pump runs dry.
• Check that the electrical connection is
220V~ - 240V~ 50Hz
GB | 25