4.11 Remote control for „Power Sharing" RPS-01
If the Remote control RPS-01 is installed, the
Trimmer (26) "INPUT LIMIT" has to be set on the
value max.. The HP-COMPACT takes into
account the lowest values set on the inverter
and on the Remote control.
The current available at the HP-COMPACT input
will be determined by the power of the
connected source (generator, grid etc...). The
potentiometer on the RPS-01 must be adjusted
lower or equal to max. value of the power
source.
For instance if the source is a generator of 2000
Watt, the potentiometer has to be set at max.
8A. This value is obtained in dividing 2000 Watt by 230V. If the HP-COMPACT is
connected to a power source which is protected by a 6A circuit breaker, the
potentiometer must be set at a max. value of 6A.
Caution: the HP-COMPACT will not limit if an appliance draws more current
than available from the source ! This means that the connected generator will
be over-loaded or that the circuit-breaker before the HP-COMPACT will break.
5

Programming

The HP-COMPACT is equipped with a Flash processor fitted out with EEPROM
Memory, which means that even when it is disconnected from the battery, the
parameters that were programmed for the application remain after a new
connection to the battery.
It is possible to reinitialize the HP-COMPACT by pressing simultaneously on
the three push buttons 19/20/21 during at least 2 seconds. A beep will confirm
the RESET. The inverter switches off after this operation. It can be turned on
again after the beep. The programmed parameters will remain.
5.1

Standard setting

The HP-COMPACT is delivered with the following default settings:
Auxiliary contact: active in case of defect or manual turn off with the LED 10/11/12/13
Battery voltage :
Absorption Time :
Equalizing Time :
5.2

Reset value (default settings)

To come back to the default settings, press simultaneously on the push buttons
20/21 during at least 2 seconds. A beep will confirm the comeback to the factory
settings. The inverter switches off after this operation. It can be turned on again after
the beep.
5.3

Battery voltages and absorption time

5.3.1 Set the voltage and timing threshold
The programming is done in accordance with the following steps:
Low voltage
Float Charge
End of Charge Voltage
Equalization
HP-COMPACT V5.7
11.6V / 23.2V / 46.4V
13.5V / 27.0V / 54.0V
14.4V / 28.8V / 57.6V
15.6V / 31.2V / 62.4V
2 Hours
20 Minutes
HP-COMPACT