STUDER Innotec
3.4
Connection Plan
Remote
L
control
RCT-01
C
D
E
F
temperature sensor CT35
remote power sharing RPS-01
M
J
A
Battery +/-
B
Reserved
C
Remote contr. Connection terminal for Remote Control RCC-01
D
Transfer delay Slide switch for Transfer Delay
E
Equalize
F
Temp.
G
Aux. Contact Connection terminal for Auxiliary Contact
H
AC Input
J
ID Plate
K
AC Output
L
Reserved
M
Hole
N
Protection
3.5
Cabling
Connecting the HP-COMPACT is a very important step of the installation. You must
take care that all connection work is carried out in a clean and correct way and that
under no circumstance a cable is connected to a wrong terminal.
Connecting of the HP-COMPACT must be carried out in the following order. In case
of dismantling this order must be reversed.
3.6
Pre-installation settings
Before you start with the cabling of the HP-COMPACT you must set the type of
battery. In case sealed-gel batteries are used then you must set the small slide-
switch „Equalize" which is on the front with the connection terminals, in OFF position.
In case of „normal" lead-acid – batteries, these can handle a higher equalizing
B
A
Battery
Connection terminal (M8) for battery cable (HPC 4400-24/6000-
48/8000-48 with fuse)
-
Slide switch for equalization of the Battery
Connection terminal for Temperature sensor CT-35 and/or
Remote Power Sharing RPS-01
Connection terminal for AC-input
Identification plate with Technical data and Serial number
Connection terminal for AC-output
-
Pass through hole for RCC-01, CT-35 and RPS-01
Thermal circuit breaker 30A (50A for HPC 8000-48) for the
Transfer system
HP-COMPACT V5.7
HP-COMPACT
H
G
L
N
Auxiliary
AC in
contact
N
K
L
N
AC out
11/80