FUNCTION
MIN. ÷M AX.
. 4
0 ÷ 6
. 5
0 ÷ 1
. 6
0 ÷ 2
. 7
0 ÷ 3
. 8
0 ÷ 99
. 9
0 ÷ 4
1. 0
0 ÷ 98.
1. 1
0 ÷ 80.
1. 2
-
1. 3
-
1. 4
0 ÷ 1
1. 5
0 ÷ 17
0 ÷ 1
1. 6
0 ÷ 50
1. 7
1. 8
0 ÷ 6
6 = If intercepted during the closing phase, it stops the gate motion; when the photocell is
freed it immediately restarts closing. If intercepted during the opening phase, as soon as
it is freed, it stops the opening motion and starts closing.
PHOTOCELL SAFETY SWITCH
0 = No function.
1 = With the gate open in pause, if the photocell is intercepted and freed, the pause time is
reset and the gate starts closing.
FRAME DURING OPENING PHASE (11-6)
0 = Absent
1 = If intercepted during the opening phase, it stops and inverts the closing m otion for 2
seconds; the flashing light will remain on and the gate will not perform any manoeuvre
until the stop or emergency button is pressed. After the stop, a start pulse will restart
gate opening. In the closing phase, the frame is not active.
2 = If intercepted during the opening phase, it stops and inverts the closing m otion for 2
seconds; the flashing light will remain on and the gate will not perform any manoeuvre
until it receives a start pulse which will restart gate opening. In the closing phase, the
frame is not active.
PEDESTRIAN GATE BUTTON (9-6)
0 = Sequential open-pause-close-stop-open etc. com m and
1 = Sequential open-pause-close-open etc. com m and
2 = Sequential open-close-open etc. com m and
3 = Open-only command; closing may be automatic or controlled by the closing button.
PEDESTRIAN GATE TIME
Adjustable between 0 and 99 seconds.
START BUTTON (8-6)
0 = Sequential open-pause-close-stop-open etc. com m and
1 = Sequential open-pause-close-open etc. com m and
2 = Sequential open-close-open etc. com m and
3 = Open-only command; closing may be automatic or controlled by the closing button.
4 = DEAD M AN'S LOGIC function. The button executes opening only if it is held pressed
down. Closing may be controlled by holding the closing button pressed down. Should
any safety device intervene, the motion is stopped.
OPERATING TIM E
Adjustable between 0 and 198 seconds. Hundreds are signalled on the display with a dot to
the right of the number. Example: 198 seconds will be displayed as (98.).
PAUSE TIME
Adjustable between 0 and 180 seconds (80.) CAUTION: 0 = INFINITE PAUSE. Hundreds are
signalled on the display with a dot to the right of the number. Example: 180 seconds will be
displayed as (80.)
FUNCTION NOT USED
FUNCTION NOT USED
WATER HAMMERING (NOT USABLE WITH SLIDING GATES)
TORQUE REGULATOR
0 = Torque regulator off
1 = Torque regulator at minimum
17 = Torque regulator at maximum
TORQUE REGULATOR INTERVENTION M ODE
0 = Intervention stops the opening or closing motion.
1 = Intervention in the closing phase stops and inverts the motion. In the opening phase it
stops the motion. Warning: during deceleration at the end of a manoeuvre the intervention
of the torque regulator will stop both closing and opening movement.
DECELERATION TIME AT END OF MANOEUVRE
0 = Function not active.
Adjustable betw een 1 and 50 seconds. This function sets how long before the end of
operation the deceleration phase m ust start. Exam ple: operating tim e = 40 seconds,
deceleration tim e = 5 seconds, after 35 seconds of opening or closing the m otor slows
dow n.
DECELERATION SPEED AT END OF MANOEUVRE
0 = Function not active (maximum speed – no deceleration).
1 = Minimum deceleration
6 = Maximum deceleration.
DESCRIPTION
DEFAULT
0
0
0
0
20
0
30
0
0
0
0
0
0
0
0
21