RE 30082/06.12 VT-VPRAP1-540-1X/.../SI
Technical data (For applications outside these parameters, please consult us!)
Error message
– Cable break actual value
– U
too low
B
– ±15 V stabilization
– Flushing circuit active
Circuit board format
Plug-in connection
Ambient temperature
Storage temperature range
Weight
Notice:
Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).
Additional information
Application
Dynamic and energy-saving pump adjustments are achieved by the
combination of a radial piston pump with a high-response valve.
Integration of the pump into a pressure control circuit allows
for realization of dynamic pressure controls. The p/Q closed-
loop control amplifier required for that purpose consists of
a basic card with front plate containing the valve amplifier
with position control as well as an attached daughter card on
which the actual pressure control is realized.
Example
Pump for open circuit
Control by preload valve block
Electro-hydraulic
adjustment
High-response valve
z22: Open collector output to +U
Max. 100 mA; error: 0 V
Only with 0811405160
mm (100 x 160 x approx. 35) / (W x L x H)
Europe format with front panel 7 TE
Connector DIN 41612 – F32
°C 0...+70
°C –20...+70
m 0.48 kg
X
X1
T
M1
L
T
P
s
U
B
A
s
U
A(B)
U
E
p/Q control card with valve amplifier
Hydraulics Bosch Rexroth AG
B
These amplifiers are only supplied as complete combinations.
In connection with the corresponding high-response valve
and pressure sensor, flows can be controlled and pressures
can be regulated in the closed control loop. The input vari-
ables are the pressure p and flow Q command values. Pres-
sure, PL valve spool position and cam position are fed back
as actual values.
Control block with preload valve,
pressure relief valve and pressure sensor
M2
M3
F
B
P
A
B(A)
X2
P
U
Pressure sensor
L
5/12