1. GENERAL INFORMATION
a. Yourheatercomesfullyassembledandistestedatthefactory
for proper gas and input as stated on the name plate.
b. Beforeproceedingwiththeinstallation,besuretoinspectfor
damages.Freightcompanymustbenotifiedofanydamages
andrequestthattheinspectionbemade.MR.HEATERwill
sendreplacementpartsfordamagedpartsonlyafterreceiving
asignedinspectionreporttoprovetheliabilityofthefreight
company.
c. Do not attempt to operate heater with any other gas than that
indicated on the heater name plate.
d. Theinstallationofheatermustconformwithlocalbuilding
codes,orinabsenceoflocalcodes,withtheNationalFuelGas
Code,ANSIZ223.1a/NFPA54,andStandardforStorageand
HandlingofLiquefiedPetroleumGases,ANSI/NFPA58.
e. CanadianinstallationsmustcomplywithCAN/CGA-B149.1.2
GasCodewhichcanbepurchasedfromtheCSA(Canadian
StandardsAssociation)website@http://www.csa.caorby
calling1-800-463-6727.
f. Plugged1/8"N.P.T.TestGageConnectionislocatedonthe
HeaterGasValveora¼"N.P.T.Connectionislocatedonthe
outsideoftheCastVenturi.
g. Contactthefactorywhenapplianceistobeinstalledathigh
altitudes.Factorysupplieshigh-altitudeconversionkitswith
instructions and data plates.
For additional information, contact;
MR.HEATERCORPORATION
CUSTOMERSERVICEDEPT.
CLEVELAND,OHIO
1-800-251-0001
MODEL
BTU/HR. RATING
NO.
NATURAL
MH/HS40NG
40,000
MH/HS40LP
—
MODEL
OPERATING
NO.
PRESSURE
MH/HS40NG
6.8"w.c.
MH/HS40LP
10"w.c.
BTU/HR. RATING
MODEL
GAS
NO.
NAT.
MH/HS40NG
40,000 —
MH/HS40LP
—
Table 1. BTU Ratings and Supply Pressures
GAS
PROPANE
NAT.
—
6.8" W.C.
40,000
—
Table 2. Heater Dimensions and Orifice Sizes
ORIFICE SIZE
BURNER
PILOT
37
.023
50
.015
Table 3. Installation, Ventilation and Mounting Information
NORMAL
MOUNTING
L.P.
POSITION
HORIZ-30˚
40,000
HORIZ-30˚
Model # MH40NG/LP
*ThefollowingextraNFPAmanualsarehelpfulwheninstalling
MR.HEATERinalocationnotanticipatedinthismanual:
Number
NFPA88
NFPA409
DONOTEXCEED½PSIINLETPRESSURETOHEATER
2. CLEARANCES
Minimumclearancestocombustibles(RefertoTable3)..Also
betweencontrolendofheaterforservicingandminimumontop
andsidesforventilationandcombustionairsupply.
Aminimumclearanceof8'abovefloorforpublicgaragesin
accordancewithANSI/NFPANo.409mostrecentedition,orTable
3;thelargerdimensionofANSI/NFPANo.409orTable3istobe
used.
*WhenselectinginstallationlocationsforMR.HEATERensurethat
theopeningofanyexteriororinteriordoorsorwindowswillnot
violateclearancesorcontactanyheatercomponents.
GAS SUPPLY PRESSURE (W.C.)
MIN.
MAX.
L.P.
NAT.
L.P.
—
7" W.C.
—
11" W.C.
—
14" W.C. —
INPUT
BTU/H
WIDTH
40.000
19-1/4"
40,000
19-1/4"
CLEARANCES TO COMBUSTIBLE SURFACES
TOP
SIDES
34"
30"
34"
30"
3
Installation Instructions and Owner's Manual
Related Subject
ClearancestoCombustibleSurfaces
ClearancestoCombustibleSurfaces
ORIFICE
MANIFOLD
NAT.
L.P.
NAT.
5.8"
—
37
10"
—
SIZE
LENGTH
HEIGHT
30-1/4"
12"
30-1/4"
12"
BACK
BELOW
30"
68"
30"
68"
SIZE
L.P.
—
50
WEIGHT
25 lbs.
25 lbs.