WARNING:
YOURSAFETYISIMPORTANTTOYOUANDTOOTHERS,
SOPLEASEREADTHESEINSTRUCTIONSBEFOREYOU
OPERATETHISHEATER.
GENERAL HAZARD WARNING:
FAILURETOCOMPLYWITHTHEPRECAUTIONSAND
INSTRUCTIONSPROVIDEDWITHTHISHEATER,CAN
RESULTINDEATH,SERIOUSBODILYINJURYAND
PROPERTYLOSSORDAMAGEFROMHAZARDSOF
FIRE,EXPLOSION,BURN,ASPHYXIATION,CARBON
MONOXIDEPOISONING,AND/ORELECTRICALSHOCK.
ONLYPERSONSWHOCANUNDERSTANDANDFOLLOW
THEINSTRUCTIONSSHOULDUSEORSERVICETHIS
HEATER.
IFYOUNEEDASSISTANCEORHEATERINFORMATION
SUCHASANINSTRUCTIONSMANUAL,LABELS,ETC.
CONTACTTHEMANUFACTURER.
THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNINGS:
WARNING:
Combustionby-productsproducedwhenusingthisproductcontaincarbonmonoxide,achemical
knowntotheStateofCaliforniatocausecancerandbirthdefects(orotherreproductiveharm).
WARNING:
ThisproductcontainschemicalsknowntotheStateofCaliforniatocausecancerandbirthdefects
orotherreproductiveharm.
CONTENTS
Specifications . ................................................................... 2
SafetyPrecations . .............................................................. 3
Storage&Service............................................................. 5
WiringDiagram170QFAVT . .............................................. 6
PartsListQ170FAVT......................................................... 7
ExplodedViewDrawingQ170FAVT . .................................. 7
Warranty and Service ......................................................8
GENERAL INFORMATION
RETAINTHISMANUALFORFUTUREREFERENCE.
FORQUESTIONS,PROBLEMS,MISSINGPARTSBEFORE
RETURNINGTORETAILERPLEASECALLWITHMODEL
NUMBERANDSERIALNUMBEROFHEATER:
1-800-321-0001
MONDAY-FRIDAY8-5PMEASTERNTIME
OREMAILUSINGTHEMR.HEATERWEBSITE:
WWW.MRHEATER.COM
Operating Instructions and Owner's Manual
WARNING:
CARBON MONOXIDE CAN KILL YOU
NOTFORHOMEORRECREATIONALVEHICLEUSE,
USINGAPORTABLEHEATERINANENCLOSEDAREA
CANPRODUCEDEADLYCARBONMONOXIDE.
WARNING:
FIRE,BURN,INHALATION,ANDEXPLOSIONHAZARD.
KEEPSOLIDCOMBUSTIBLES,SUCHASBUILDING
MATERIALS,PAPERORCARDBOARD,ASAFEDISTANCE
AWAYFROMTHEHEATERASRECOMMENDEDBYTHE
INSTRUCTIONS.NEVERUSETHEHEATERINSPACES
WHICHDOORMAYCONTAINVOLATILEORAIRBORNE
COMBUSTIBLES,ORPRODUCTSSUCHASGASOLINE,
SOLVENTS,PAINTTHINNER,DUSTPARTICLESOR
UNKNOWNCHEMICALS.
SPECIFICATIONS
MODELNO................................................. 170QFAVT
GASTYPE . ...................................................... Propane
BTURATING...........................125,000-170,000BTU/hr
GASSUPPLYPRESSURETOREGULATOR
Maximum:BottlePressure,Minimum: 20psig(137.9
kPa)
REGULATOROUT...............................20psi(137.9kPa)
ELECTRICALINPUT........................1 15V,60Hz,1Ø,3a
IGNITION....................... DirectSpark,interruptedtype
PRIMARYFLAMECONTROL . ..
HIGHTEMPERATURECONTROL...................
MinimumAmbientTemp.Rating:0°F(-17.8°C)
FUELCONSUMPTION..........................5.8-7.9lbs/hr
FUELORIFICEPORTNO.: ...........................................1
FUELORIFICEPORTSIZE: .......................1.48±0.01mm
HEATEDAIROUTPUT:........450CFM(12.74cum/min)
Inordertoprovidethebestservicepossible
Mr.Heaterisnowgivingyoumorewaysto
getintouchwithus:
FACEBOOK:Findusonfacebook
TWITTER:Findusontwitter
YOUTUBE:Therearenowinformationalvideos
onYouTube.
WEBSITE:Mr.Heater'sfulllineofproductarenowat
WWW.MRHEATER.COM
2
Force-Air Propane Construction Heater
SolidState,10-15sec.timing
240°F(116°C)