Install Pipe Stop Bracket
For direct-vent applications, attach the pipe stop bracket to the
rear shroud with the two 8 x 3/8" phillips pan head screws. See
Figure 32.
Insert the blue intake connector gasket into the inlet air opening
in the rear shroud. See Figure 33.
Page 22
WALL FURNACE INSTALLATION
MOUNTING THE REAR SHROUD
Figure 32
Figure 33
Installing Rear Shroud
After cutting the opening for the vent and gas line, place the shroud
back into position against the wall and secure in place. The shroud
should be mounted to the wall studs, if possible, using the four 10
x 1-1/2" hex-head screws provided. Two screws in top holes and
two screws in bottom holes. See Figure 34.
If installing the wall furnace on the floor, the rear shroud may be
anchored solidly to the wall using the four plastic anchors (not
provided) and four 10 x 1-1/2" (38mm) hex-head screws (provided).
DO NOT use plastic anchors if installing the wall furnace off
of the floor. The wall furnace must be secured to the studs;
it may fall causing damage possible harm. Wall furnaces
installed on the floor may be secured to the wall may use
plastic anchors.
Figure 34