If the panel heater is disconnected from the mains
EN
this will not change the temperature settings and the
operation mode which have been enabled entered before
its disconnection. If, for example, the panel heater has
been set to "Heating" mode, after disconnecting and
re-connecting the appliance to the mains it will stay in the
same operation mode, at the same temperature settings.
When the room temperature is lower than the
temperature settings you have selected by the thermo
regulator, the panel heater starts operating and will
continue to operate until the room temperature
reaches the adjusted temperature settings of the
appliance. When the room temperature is higher than
the temperature which has been set by the thermo
regulator, the panel heater will automatically go into
"Stand by" mode.
Information presented on panel heater display
When connecting the panel heater to the power system
the display shows:
•
two lines "-- ", when the panel heater was in turned-
off condition at the time of disconnection.
•
two lines "--", which after 2 seconds are replaced
with the current temperature readings, if it was in
turned-on condition at the time of disconnection.
•
two figures in combination with blinking yellow
diode light, which show the remaining time in hours
until the delayed start, if the panel heater was in
"Delayed start" mode the time of disconnection.
In order to achieve additional economy of electricity,
the thermo regulator diminishes the brightness of
illumination of all the indicators. When pressing any
button, brightness increases for 8 seconds and after that
it is diminished again.
If the display presents "t0" or "t1", this means that the
self-testing system has detected a problem in the thermo
sensor. "t0" stands for disconnected cable, "t1" stands
for short circuit in the sensor. In this case the heater gets
turned-off and its next activation will be possible after
solving the problem. The malfunction must be repaired by
a qualified technician.
When connecting the appliance to the power system,
the display will show for up to two seconds two lines "--"
instead of temperature or time.
If the room temperature falls below 5 degrees and the
panel heater is off (red diode light is off) the heater will turn
on automatically in order to prevent freezing of the unit.
When the digital display shows temperature –
"Temperature LED" is on, and when time until delayed start
or stop is shown the "Time LED" is on.
6
Operation and Storage Manual
MECHANICAL CONTROL
Operation modes
Turn the panel heater on by pushing the switch in
position "I" (turned-on), then turn the regulator to
the desired level (1 to 6) as you take into account the
following relation between the power levels:
* – anti-freezing mode/ enabled when room
temperature falls below 5°C
1 / 2 – economy mode/ it maintains low room
temperature/ this mode is recommended to be used
at night and when there are no people present in the
room. This mode permits to maintain the set room
temperature while saving energy.
3 / 4 / 5 – comfort mode/ it maintains moderate room
temperature/ this mode is recommended to be used to
maintain relatively high comfortable room temperature
during the day.
6 – maximum power mode / it maintains HIGH room
temperature/ this mode is recommended to be used
when you need maximum high room temperature
Important: Thermo Regulator digits do not correspond
to certain room temperature levels, but they can be used
by users to memorize the relation between room temperature
and the thermo regulator settings.
When the room temperature is lower than the
temperature that you have set by the thermo regulator,
the panel heater starts its operation and will operate
until the room temperature reaches the set temperature
level of the unit. When the room temperature is higher
than the adjusted temperature of the appliance, the
panel heater will automatically go into "Stand by" mode.