2. TRANSPORT AND INSTALLATION
Knocks and sudden movements must be avoided when transporting the equipment. The transport position
will be shown by arrows on the packaging. In any case, the equipment must be kept horizontal and the
packaging protected from water.
GALA MIG 3000/3800 assembly
Once the equipment has been unpacked the wheels must be mounted:
2.1. ELECTRICAL SUPPLY INSTALLATION.
The welding equipment location must satisfy the following requirements:
Place: Dry and ventilated, far enough away from the cutting area in order to prevent the metal dust caused
by the cutting process from getting into the equipment.
Electrical installation. Electrical elements of the installation.
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
GALA MIG 3000/3800.
Protection system
Connection
plug.
Magnetothermal
switch (Curve
"D")
Differential
switch.
(Minimum)
6º
GALA MIG
3000
GALA MIG
32A 3P + T - 230V
32A 3P + T - 230V
16A 3P + T - 400V
16A 3P + T - 400V
3P 20 A - 230V
3P 15 A - 400V
3P 25A/300 mA
3P 25A/300 mA
3º
2º
4º
5º
3800
3P 25 A - 230V
3P 20 A - 400V
17
7º