3 Caractéristiques techniques
Connecteur
Dénomination anglaise
CT1
Inductor
CT2
Inductor
CN1-35
Terminal base
SW2_1
Disinfect temp. 70°C/65°C
SW2_2
With disinfect/ without disinfect
SW3_1
Electric heater 1550W
SW3_2
With E-heater/ without E-heater
Main control board
Power supply
Black
Blue
Brown
Orange
Gray
Red
White
Yellow/Green
N
Neutral
L
Phase
GND
Ground
T5
Temperature sensor of the tank
T3
Evaporator temperature sensor
T4
Ambiant temperature sensor
TP
Discharge air temperature sensor
TH
Suction temperature sensor
POWER1
Power supply of the main control board
COMP.F
Compressor
Compressor capacitor
EEV
Electronic expansion valve
TR
Transformer
FAN
Fan
CAP1
Fan capacitor
LCD
Display
Electric heater
RY12, RY13
Relay connection wires
KM1
Electric heater control board
KM2
Relay
TCO
Thermal Cut Out
ATCO
Automatic Thermal Cut Out
Wiring diagram of tank inside
Wire comes from out from tank, must connect with
1A/1B/T5
the corresponding component
XT1, XT2
Mid terminal base
XP1, XP2
Connector
XS1, XS2
Connector
20
Française
Inductance
Inductance
Bornier
Température consigne 70°C/65°C
Mode anti-légionelle activé/désactivé
Résistance électrique 1550W
Avec rés. Électrique/ Sans rés. Électrique
Carte régulation
Alimentation électrique
Noir
Bleu
Brun
Orange
Gris
Rouge
Blanc
Jaune/vert
Neutre
Phase
Terre
Sonde de température d'eau
Sonde température de l'évaporateur
Sonde température air ambiant
Sonde refoulement compresseur
Sonde aspiration compresseur
Alimentation carte régulation
Compresseur
Condensateur du compresseur
Détendeur
Transformateur
Ventilateur
Condensateur du ventilateur
Afficheur
Appoint électrique
Fils de raccordement relais
Tableau de commande de l'appoint électrique
Relais
Sonde de régulation résistance électrique
Thermostat de sécurité de l'appoint électrique automatique
Schéma de câblage intérieur du ballon
Câble provenant du ballon, doit se connecter avec le composant
correstondant
Bornier intermédiaire
Connecteur
Connecteur
7630153 - v04 - 10022016