EN 61000-3-11 and is subject to special
connection conditions. This means that use
of the product at any freely selectable con-
nection point is not allowed.
• Given unfavorable conditions in the power
supply the product can cause the voltage
to fluctuate temporarily.
• The product is exclusively intended for use
at connection points that have a continu-
ous current-carrying capacity of at least
100 A per phase.
• As the user, you are required to ensure, in
consultation with your electric power com-
pany if necessary, that the connection point
at which you wish to operate the product
meets the specified requirements.
Important information
In the event of an overloading the motor will
switch itself off. After a cool-down period (time
varies) the motor can be switched back on
m
WARNING
Remove the plug from the wall socket when working on the electrical power tool itself (e.g. transportation, setup,
conversion, cleansing and maintenance works)!
• Attention! Unplug the machine. Clean swarf
off the machine. Replace worn out cut off
wheels. Check carbon brushes regularly
and replace them when worn out. Replace
damaged protection devices.
again.
Damaged electrical connection cable
The insulation on electrical connection cables
is often damaged.
This may have the following causes:
• Passage points, where connection cables
are passed through windows or doors.
• Kinks where the connection cable has been
improperly fastened or routed.
• Places where the connection cables have
been cut due to being driven over.
• Insulation damage due to being ripped out
of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables
must not be used and are life-threatening due
to the insulation damage.
Check the electrical connection cables for
damage regularly. Make sure that the connec-
tion cable does not hang on the power net-
Cleansing, maintenance and repair
work during the inspection.
Electrical connection cables must comply
with the applicable VDE and DIN provisions.
Only use connection cables with the marking
„H05VV-F".
The printing of the type designation on the
connection cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must
have a cross-section of 1.5 mm2.
Connections and repairs of electrical equip-
ment
may only be carried out by an electrician.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
15
GB