Fault Messages; Notes; Special Functions; Excess Humidity Protection - Maico WR 310 Notice De Mise En Service Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UK | 8 Special functions

7.10 Fault messages

The last five faults are displayed in the
"Faults" menu along with a time and date.
Faults already rectified are listed in a logbook.
For information about faults and their rectifica-
tion  Chapter 13.
Supply air fan
Exhaust air fan
Communication with main control unit (com-
fort control unit)
Sensor T-outside air upstream of EHE
Sensor T-air inlet device
Sensor T-outgoing air
Sensor T-supply air
Sensor T-room external
Sensor T-room control unit
Sensor T-room KNX
System memory
System bus
Combi sensor
Additional circuit board 1
Additional circuit board 2
Bypass
Supply air temperature too cold
Exhaust air temperature too cold
Frost protection
Zone shutter
External pre-heating
Pressure consistency setpoint not reached

7.11 Notes

Notes provide information about the current
system statuses along with a time and date.
An overview with possible notes is provided in
Chapter 13.5.
80

8 Special functions

8.1 Excess humidity protection

310/410 320/470
Flat
Trio
Excess humidity protection protects the apart-
ment from excess humidity.
If the exhaust air humidity exceeds the set
humidity value limit ( Chapter 6.6), the ven-
tilation unit switches to intensive ventilation
until the room air humidity has fallen to 3 %
below the set max. value limit.
The ventilation unit then switches back to the
last ventilation level used.
The maximum humidity value limit can be set
to 50 to 70 % rel. hum.  Chapter 6.6.
This function is always active and
i
cannot be disabled. Exception: In ECO
mode, supply air operating mode, ex-
cess humidity protection is deactivated.
The control only activates excess hu-
i
midity protection if the outside air has
an absolute humidity lower than that of
the exhaust air.
Special excess humidity protection func-
tion for KBET units with enthalpy heat
exchanger, bypass and PTC heat register
310/410 320/470
If the relative humidity does not fall below the
Rel. humidity value limit max within 48 hours,
the bypass opens and the supply air is heated
with the PTC heat register.
If it then falls below the value limit, the venti-
lation unit switches back to the last ventilation
level used. The bypass closes and the PTC
heat register switches off.